Showing posts sorted by relevance for query Supply Lines included. Sort by date Show all posts
Showing posts sorted by relevance for query Supply Lines included. Sort by date Show all posts

Friday, November 17, 2017

WS Bath Collections Candy CA 071CR Single Lever Wash Basin Mixer

Read article : WS Bath Collections Candy CA 071CR Single Lever Wash Basin Mixer

Close X

image


Contractor Pack Price ()

Get AIR MILES® Reward Miles help helpBox AIR MILES® Reward Miles base offer: 1 Mile for every $20 spent Additional promotional offers, including Bonus Miles, are not included. Does not reflect any discount applied at check out.

Lowe's Item

Mfr Part #

Online Exclusive

Vendor Direct Shipping

Online Exclusive

Vendor Direct Shipping

Province

Lead-Time

Ontario

7 days or less

Sakatchewan

9 days or less

Alberta

10 days or less

British Columbia

12 days or less

*This product is a special order item and available to purchase online or by speaking to an associate at this selected store. Choose from store pick-up or home delivery. Standard charges apply for home delivery. (learn more)

*This product is a special order item and is not stocked in your local Lowe’s store. This product will be shipped directly from the manufacturer. Dates available for delivery or in-store pickup may vary from the estimates displayed above. (Learn More)
image

Product Description

 

Available while supplies last.

This single lever wash basin mixer by WS Bath Collections is part of the Candy collection.

Finish:Polished Chrome
Materials:Solid Brass Base
Warranty:1 Year Limited
Bathroom Faucet Special Features:Supply Lines included

Dimensions & Weights 

Spout Reach:5.8 inches
Height:5.8 inches

Items In This Collection 

$360.00Your total:

Add to Cart

Add to cart to configure options

   

Tag This Product

Additional Details

Mfr Part #:
Sku:
UPC #:
Group #: 2647331
Category: Bathroom Faucets - 456
Style: Modern - 3
Sales Rank: 94

5513342|7595938|12192716|12564882|7595957|9091607|12886833|12886840|12886839|12886838|12886832|12886833|

"; var altImgSectionCount = 1; var isObsolete = false; var intGId = 2647331; var intBaseSku = 12886833; var intMfrId = 3614; var strGroupImg = "3614/candy-ca-071-1.jpg"; var bolHidePrice = false; var bolHideSavings = "False"; var bolHideAddToCart = false; var gDim = true; var defImgTxt = ""; var optionKey = ""; var strKey = ""; var shippingType = ""; var storeAvailability = 0; var sRecent = new Array('12886833','2647331','360.0000','3614','candy-ca-071-1.jpg','WS Bath Collections Candy CA 071CR Single Lever Wash Basin Mixer'); var arrOptions = new Array();arrOptions['12886833'] = {optionKey:''}; var arrOpt = new Array();arrOpt[''] = {price:360,msrp:432, d:'Height: 5.8in |Spout Reach: 5.8in |Box Dimensions: 12in x 10in x 8in |Ship Weight: 12lbs',sku:12886833,ac:152.00,ship:76.80,cShip:0.00,img:'candy-ca-071-1.jpg',imgT:'',oImg:'170996_option.jpg|',shipW:0,leadL:3,leadU:6,partNo:'Candy CA 071CR',invChk:'10/3/2017',mfrStk:'2',stkShip:'0',bo:'',desc:'',osum:'',upc:'',lowesItemNum:'0',wasPrice:'0.00',packQty:1,ship_via:'Ground',freightUpgradeLvl1:'0.00',site:'plumb',clearancePrice:0.00,compareData:'',shipTimeCutOff:'12:0', shipTime:'Oct 6th - Oct 11th', canPurchase:true, canPurchaseReason:'Vendor submitted in stock inventory.', priceType:200, endDate:'Dec 31, 2020', bannerFlag:0, preOrderAvailOnDate:'', stkQty: '', SEODesc:' This single lever wash basin mixer by WS Bath Collections is part of the Candy collection. ', serviceContract:'', photoType: 0, photoImg: '', bulkPrice: null, bulkQty: null, bulkDiscount: null, store: 1, truck: 1, parcel: 1, lfpOutOfStock: 0, unitsPerSku: '', sellPrcType: 0, leadTime: 10/3/2017, vendorDirect: 'False', sosCheck: 'none', posRestrictionReason: '', posRestrictionStartDate: '', posRestrictionEndDate: '', posRestrictionStoreLocation: '', posRestrictionZipCode: '', posRestrictionStateCode: '' , pricePerUnitOverride : '0', sosItemNumber : 0, override : 0, hidePriceReason: 'False', hasSkuImg: 0, serviceFamilyId: 0, porchToggle: 'False', isServiceFamilyIdObsolete: 'False', intGuaranteed: 0, intInStoreOnly: 0, catalogItemMinQty: 1, orderQtyMultiple: 1, isSoS: 0, isSoE: 0 }; var arrSku = new Array();arrSku[0] = 12886833; var allSkuString = "|"; var cSku = "0"; var siteName = "lowesca"; var groupName = "WS Bath Collections Candy CA 071CR Single Lever Wash Basin Mixer"; var typeName = "Bathroom Faucets"; var rootPart = "Candy CA 071CR"; var mfrName = "WS Bath Collections"; var hasInternalFlashVideo = false; var isUsingProdSetImg = false; var dblMaxSavings = 72; var isProdSet = 0; var flowplayerKey = ""; var hasCountdown = "False"; var rewardsMultiplier = 1; var isInStoreOnly = false; var intTypeId = 456; var bolIsRequiredOutOfStock = false; var intInventoryOverride = 0; var strVidPlayerType = ""; var intCurProdSet = -1; var dynamicPriceDiffers = false; var hasAccessories = 0; var hasAssembly = false; var hasCustomization = 0; var bolIsBundle = false; var mfr_prod_id = "Candy CA 071CR"; var custshippingcost = "0"; var permalink = "www.lowes.ca/bathroom-faucets/ws-bath-collections-candy-ca-071cr-single-lever-wash-basin-mixer_g2647331.html"; var psGroupName = ""; var strGroupImg = '//images.lowes.ca/img/p400/3614/candy-ca-071-1.jpg'; var strLowesLeadTime = ''; var intCurImg = 0; var strUom = ''; var arrOptOrder = null; var arrSwatches = {}; var intSingleWarehouse = 0; var strImgDomain = '//images.lowes.ca'; var bolMfrShowSwatches = false; var intMinQty = 1; var intMultipleQty = 1; var intGuaranteedByType = 0; var intMinSku = 12886833; function openInternalNotes(sku){ var ajaxReqObj = new ajaxRequestObjectCache("/ajax/prodNote.aspx", "sku=" + sku, showProdNotes); ajaxReqObj.doGetCallback(); } function showProdNotes(strData){ document.getElementById("internalNotes").innerHTML = strData; } function openAtgInfo(mfrId){ document.getElementById('divATGInfo').style.display = 'block'; var ajaxReqObj = new ajaxRequestObjectCache("/ajax/shipCarrier.aspx", "mfr_id=" + mfrId, showCarrierInfo); ajaxReqObj.doGetCallback(); } function showCarrierInfo(strData){ document.getElementById("divCarrier").innerHTML = strData; } function loadDefVideo() { } function openPopUp() { var sku; var rv = -1; if (navigator.appName == 'Microsoft Internet Explorer') { var ua = navigator.userAgent; var re = new RegExp("MSIE ([0-9]{1,}[\.0-9]{0,})"); if (re.exec(ua) != null) rv = parseFloat( RegExp.$1 ); } if(rv == -1) { sku = document.getElementById("spnPartNumber").textContent; } else { sku = document.getElementById("spnPartNumber").innerText; } if(sku.charAt(sku.length - 1) == "S" || sku.charAt(sku.length - 1) == "s") { openPopBox(524, 390, ""); } else { document.getElementById("optError").style.display = "block"; } } function openPopUpCata() { if (undefined === arrOpt[strKey] || null === arrOpt[strKey]) showOptError(); else { var sku = document.getElementById("spnPartNumber").innerText; var rv = -1; if (navigator.appName == 'Microsoft Internet Explorer') { var ua = navigator.userAgent; var re = new RegExp("MSIE ([0-9]{1,}[\.0-9]{0,})"); if (re.exec(ua) != null) rv = parseFloat( RegExp.$1 ); } if(rv == -1) { sku = document.getElementById("spnPartNumber").textContent; } if( sku != null && sku != 'undefined' && sku != ''){ //open up iframe to catalog openPopBox(165, 145, ""); }else{ //has customerID but no catalog window.location.href = "/pro/manageCatalogs.aspx"; } } } function openPopUpAddCatalog() { var sku = document.getElementById("spnPartNumber").innerText; var rv = -1; if (navigator.appName == 'Microsoft Internet Explorer') { var ua = navigator.userAgent; var re = new RegExp("MSIE ([0-9]{1,}[\.0-9]{0,})"); if (re.exec(ua) != null) rv = parseFloat( RegExp.$1 ); } if(rv == -1) { sku = document.getElementById("spnPartNumber").textContent; } window.location.href = "/pro/manageCatalogs.aspx"; } $(function () { var msie6 = $.browser == 'msie' && $.browser.version = top) { // if so, ad the fixed class $('#scrollup').addClass('fixed'); } else { // otherwise remove it $('#scrollup').removeClass('fixed'); } }); } //custom catalog code if((siteName == "lfp" || siteName == "atgs") && readCookieViewPage("user%5Fid") != null && readCookieViewPage("user%5Fid") != ""){ var currentdate = new Date(); var datetime = "Last Sync: " + currentdate.getDate() + "/" + (currentdate.getMonth()+1) + "/" + currentdate.getFullYear() + " @ " + currentdate.getHours() + ":" + currentdate.getMinutes() + ":" + currentdate.getSeconds(); $.ajax({ url : '/ajax/CustomCatalogHandler.ashx', type : 'GET', data : { 'random' : datetime }, success : function(data) { if(typeof data != 'undefined' && data != null && data != ""){ if(readCookieViewPage("ProAdmin") == 1){ $("#litAddToCatalog").empty().append(data); } } }, error : function(request,error) { } }); } }); function readCookieViewPage(name) { var nameEQ = name.toLowerCase() + "="; var ca = document.cookie.split(';'); for (var i = 0; i Candy CA 071CR" id="dtmProductID" />

Saturday, May 6, 2017

Copper pipe electrolysis from touching galvanized steel?

Read article : Copper pipe electrolysis from touching galvanized steel?
topic 24664

An ongoing discussion from 2003 through 2016 . . .

(2003)electrolysis in copper pipe

Q.I recently had a 1/2" TYPE L HMP flexible copper pipe that sprung a leak, unfortunately it was inside the wall going up to the second floor. After splicing the pipe where it was leaking another spot started leaking. I noticed inside the pipe a bunch of green "blobs" & the outside of this (HOT) water pipe a lot cleaner than the other pipe (COLD) that would have been put in at the same time, 20-25 years ago I'm guessing. I did notice one spot where the copper pipe was touching an old galvanized pipe seemed to be wet and green. Could there have been some electrolysis going on that caused this pipe to start getting finer than pin hole leaks & how much damage might have been done to the rest of the plumbing if that is the case?

THANK YOU FOR YOUR HELP,

Alex H [last name deleted for privacy by Editor]
do-it-myself-er - Cedar Rapids , Iowa

(2003)

A.Copper pipes can corrode in at least three different ways, but the differences are quite technical. I would suggest that the corrosion could be induced by a galvanic couple caused by contact with the galvanised pipe and this results in an induced local anodic polarisation of the copper pipe. I would normally expect such a failure to occur where the two pipes come into contact, but if this point is dry, no corrosion will occur and the effects of the galvanised pipe will be transmitted onto the copper pipe where it will react in a more favourable wet environment. Your photograph clearly shows the green copper salts on the inside of the failed straight pipe, so it must have been in an area where the copper is oxidised and failed. The propensity for copper pipes to fail is related to how the pipe was made, the local water composition and the environment it is used in. I would suggest there may be other not be other problems with your copper pipes, as there has already been a failure of an induced polarity, but if there are other non-compatible pipes in contact with each other, there could be a repeat of this. It may be wise to ask a plumber to check your system out.

trevor crichton
Trevor Crichton
R&D practical scientist
Chesham, Bucks, UK

(2004)

Q.I was told by a local plumber that electrolysis can occur in copper pipes when the hot water heating system is part of a forced hot water boiler system. The solution is to put nylon fittings between the copper connections and the galvanized boiler system so as to prevent any electrolysis action from taking place in the copper pipes running throughout the building. I would like to get other opinions since this is an expensive fix and it takes a long time to determine whether the fix in fact works.

Dan W [last name deleted for privacy by Editor]
property management - Juneau, Alaska

(2004)

A.It is the right advise, Dan. For galvanic corrosion to occur you need a metallic circuit and an electrolyte circuit. If you break the conductive metal circuit between the copper and galvanized pipe, galvanic corrosion ("electrolysis")" does not occur. This is not to say that no form of corrosion will ever occur though.

Ted Mooney, finishing.com
Teds signature
Ted Mooney, P.E. RET
finishing.com
Pine Beach, New Jersey
(2004)

A.Copper pipe failure began to occur approximately eight years after completion of a new home in Brewster Co. Texas. The leaks were always in the cold line.

A split-core ammeter revealed a slight current flow between the steel gas pipe and the hot side of the copper system. No current could be detected between the cold copper pipe and the hot, or the steel gas line. This led me to conclude that the cold line was acting as a sacrificial anode between the other two while absorbing all voltage drop.

No electrical bonding could be found.

My solution was to isolate the steel line (which included some galvanized parts), from the copper system with a PVC adapter.

Current flow cannot now be detected unless a jumper is placed between the steel and copper.

Is the problem solved? I don't know! What can be said is that there is no further measurable evidence of electrolytic activity in this particular system.

Sam D [last name deleted for privacy by Editor]
- Alpine, Texas
(2004)

A.As others have mentioned, there are three different ways for holes to develop in a copper line, and I have seen all three.

A typical trade mark of electrolysis is pit on the inside of the pipe where the electrical current has actually eaten away at the piping, this doesn't sound like what is going on.

Another way is corrosion from the outside, normally when the piping in in a damp location with high acid soils, or even in an unsealed sleeve (copper run inside another pipe, usually PVC, and normally from the meter to the house). This is evidenced by pitting on the outside of the pipe.

The last one I have come across, and am still researching, is what it sounds like this gentleman has. It typically will have build-up on the inside of the piping and will often times leave large "blobs" of build up. I don't know what this is for sure, but I do know it isn't electrolysis, and it has nothing to do with water that is too clean (mentioned on another website as a possible answer). I think it has to do with the water quality to a certain degree, but I think it may be the molecular structure not the chemicals used. I think the buildup is a protectant for a "micro-atmosphere" high in maybe hydrogen. But I could be wrong, I am still researching this. I will post any further findings.

Jereme Grisenti
plumbing - Blountville, Tennessee

(2005)

Q.If we were to rivet or otherwise attach a copper sleeve to galvanized chimney pipe, would this cause the galvanized pipe to fail? We have fireplace chimneys on the beach. we have several copper clad chimneys that are doing well, but the maker went out of business. Now we have only galvanized pipe to work with and the outside of it corroding causes an eye sore.

Bryan Malt
- San Diego, California
(2006)

Q.This is a piggy back question.

Three 1/2 inch copper pipes running from my basement to the Laundry room one floor above show the same kind of erosion as the picture accompanying the original question. In each case the green copper salts and pin holes developed where the pipes pass through the floor. You can see the leaking water from below but not from the laundry room level.

After one of two plumbers to replace one of the leaky pipes stated that at one point he felt a very mild electrically shock, I had an electrician check the system. The electrician said he could not find a problem. The electrician checked the system before and after the plumber felt the shock. We could not duplicate the shock with the plumber or the electrician.

The plumber reinstalled the three pipes and wrapped the new pipes in electrical tape at the point where the pipes go through the floor.

Since we have not yet found a source of electrical charge would it be prudent to ground the copper line to an unused galvanized pipe so any current would flow to the unused galvanized pipe? Any help would be appreciated.

Greg Butts
- Stafford, Virginia
(2007)

Q.When copper pipes are plastered over into walls do they need to be protected from corrosion either by cement or plaster?

Mrs M Bridger
Homeowner - Steyning, West Sussex, England
(2007)

Q.I have a brick wall in my bathroom and want to cut a groove in the brick run the copper pipe inside and cement it back up. Will this have a long term effect on the pipe
thanks daz

Dario Ruberto
designer - Toronto, Canada
(2007)

Q.I have some questions regarding electrolysis, or galvanic corrosion between the copper and galvanized water pipes in my house. The house in on a municipal system and it is my understanding that acidic or soft water is not a problem in my area.

I have extremely low pressure in the upstairs bathrooms, and moderately low on the main floor kitchen. In my basement I have galvanized pipes coming in from the street, they supply the hot water heater, and they run the hot water for a few feet beyond the tank. At one point they are connected directly to copper pipes which take the hot and cold supply upstairs to the bathrooms.

I intend to replace the galvanized pipe, but I am trying to decide whether or not to replace the copper pipes going upstairs, and as well the hot water heater.

To make this decision I need to understand a little more about what is going on with the electrolysis. Before discussing the ramifications with the hot water heater, I have the following questions:

1. Where the galvanized and copper connect in the basement, does the electrolysis happen only locally? It seems that the electrons would travel only within the magnetic field created by the metals and therefore only affect the pipes within about a foot or so of the connection. Or, since the water exists through all the pipes, does the electrolysis affect the copper all the way to the upstairs bathrooms?
2. Once the galvanized pipe is removed, will the electrolysis cease? (I understand that new copper and old copper will also create electrolysis but I assume this condition is not as severe.)
3. I understand why galvanized pipe corrodes when coupled with copper but I don't understand why it is that the galvanized pipe becomes filled with gunk on the inside and restricts flow, I would think the corroding would make it get slightly wider on the inside, not more narrow.
4. If I remove the galvanized pipe, can I clean out the remaining copper pipe to make sure there is no corrosive material setting in them? How is this performed?

As far as the hot water heater is concerned, galvanized pipe feeds it and takes the water out of it, however, there is copper flexible tubing that actually connects directly to it. I assume this means the heater has corrosive material in it and will likely not last as long. If I leave the existing heater in place and wait for it to fail, will it contaminate any new piping that I put in?

Also, if I run the new copper water service through the front yard within a few feet of the gas line will this cause electrolysis? If yes, will it affect the pipes inside the house or just in the front yard? Which pipe will get holes and which will narrow? Can I insulate the copper to prevent this?

Justin Zavislak
buyer, hobbyist - Seattle, Washington
July 13, 2008

Q.I have type k copper coming from the main to the shutoff in the house. after reporting a leak it was dug up to be repaired and all was found was a pipe with walls that have thinned considerably and covered in grooves resembling termite damage on wood. it was also riddled with pinholes.

the ground for my electrical is connected to this pipe. could that be a possible cause. please help. there other houses in the area that have had there lines replaced twice in the last 20 years.

thanks, cy

cyrus lambert
hobbyist - conne river, Newfoundland, Canada
July 20, 2008

A.Where I work they were having problems with the copper pipes. The anode rods in the water storage tanks had been all wore down. Plumbers found the electrical system grounding rod had been disconnected & everything was grounding through the plumbing, causing the problems. You might want to check but I think it is a code violation now to ground through your plumbing only.

Alex Hatfield
- Cedar Rapids, Iowa

August 30, 2008

Q.I have a problem identical to to the lead in this thread. Green spots on rigid type L 1/2 in copper pipe with water seepage. This 14+ ft run of pipe is leading from my gas fired hot water heater (after a few short copper fittings) across the drywall finished basement ceiling to a T that feeds hot water to most of the house. I noticed a small spot of mold on the ceiling, cut it open and found this pipe with green spots like the picture above and two of the spots (at different ends of this one section of pipe) have water seepage. There are several other copper pipes , cold water and feeds for hot water heating that have no green spots,(only this one length of hot water has the spots) and also a flexible gas line in the same bay. My fix is to replace this entire length. A difficult job for me, tight spaces overhead, and hope there are no other bad pipe in the house. Please confirm the cause of this. Is it likely to be elsewhere or reoccur?

David Goldman
- W Milford, New Jersey
September 3, 2008

A.In response to the gentleman who experienced a leak on a 1/2 copper pipe and then he split it exposing this thick green blob running on the inside for some unknown length. well from dealing with similar repairs and from years of experience in the field this green corrosion that you are talking about stands far from electrolysis. this green gunk/blob is what we use to solder/sweat our copper pipes with better known as FLUX this product is applied to the outside of the copper pipe once it has been cleaned and reamed. putting too much flux on the pipe and fitting will cause the excess to flow into the pipe and will settle on the inside of the pipe until the system gets energized and water flows flushing out the excess flux. if it was not flushed out and was left as is; guess what? call your plumber.....thanks.

Armando Olvera
- Costa Mesa, California

September 14, 2008

Q.Within the last 9 weeks we have called the plumber 3 times regarding a 4 ft. section of hot water copper piping. Each time a pinhole sealing leak about 4-6 feet away from a recently replaced(5 months ago that our plumber installed) electric hot water heater. After replacing 2 inch copper pipe sections at a time we finely asked him to change a length of pipe but, only last night we developed another leak, a foot over from the new pipe, closer to the water heater. Our house is 15 years old and we use city water. The leaky pipe had green discoloration at the leak points. The plumber says this problem could be expected in this area in homes using well water after about 20 years due to the highly acidic soil but we use city water and our pipes are in the sealing. He's suggesting we may need to replace all of our pipes but it seems strange that the leaks are all near the water heater. Could the water heater be faulty or it's installation be the problem?

Chris McQuillen
homeowner - Crescent City, California
September 14, 2008

A.Hi, Chris. I'd be pretty confident that is has to do with something electrical rather than well water. I think I'd call an electrician rather than calling the plumber again.

Regards,

Ted Mooney, finishing.com
Teds signature
Ted Mooney, P.E. RET
finishing.com
Pine Beach, New Jersey

(2005)September 30, 2008

Q.can a copper water line be spliced to an existing galvanized water pipe line?

Keith Medved
- Dyer, Indiana

A.Hi, Keith. When you transition from one kind of metal pipe to another, the correct thing to do is to use dielectric unions =>

These are unions that include a plastic insulator so there is no metal-to-metal contact. I'm not saying that this is always done, but it is the right way to insure that there can be no galvanic corrosion.

Regards,

Ted Mooney, finishing.com
Teds signature
Ted Mooney, P.E. RET
finishing.com
Pine Beach, New Jersey

October 24, 2008

Q.How can one determine the cause of frequent deterioration of a 3/4" copper water supply line? The section going bad is located underground at the block wall of the foundation. The home owner had to replace this line two times within the past year. The deterioration seems to occur on the outside of the pipe. There were no problems prior to the first replacement of this pipe section 9 months ago. The home has city water and uses a sump pump due to a high level of ground water. I don't know the pH level of the water. The basement is dry, but uses on a "floating slab" to channel away the ground water. I conducted load tests of the electric panel to verify the electric wiring. All tests proved satisfactory with only about .2 amps or less flowing to the ground wire. This is when a 35 amp load is applied to each 120 volt leg. This proves that practically all current is flowing back through the neutral conductor. The electric service is lacking the required two, 8 foot ground rods. There is only one ground rod, and it appears to have been installed as a ground for the telephone system. At this point I'm thinking the corrosion and deterioration was not caused by excessive current flowing top ground via this water supply line.

Dave Baylor
- Pittsburgh, Pennsylvania
May 22, 2009

Q.Hi, Our house is 6 years old and from the time we moved in we have had this "green" problem. It has ruined my hair and has left stains in the sinks and toilets. We have had 2 different water softeners and 2 water heaters. We discussed this with the last water softener person and I guess they didn't have a clue about this problem. No one has until I
talked to some nerd at the company that tests the water for the city. He said that it was probably because of the fittings that the water softener company put on the copper pipes and if we didn't rectify the problem, we would eventually have pin size holes in the pipes and leaks! What do we do, who do we call and how do we go about fixing this problem! I want long hair again! Thanks!

Kathy L. Maxwell
- Grover Beach, California
December 8, 2009

A.While replacing the copper piping in a 150 year old home, I was puzzled by the green buildup inside of the pipe. Tracing the pipe I discovered that a ground clamp and wire from the circuit breaker box was connected to the cold water line 15' from the water meter where a jumper wire was also connected to the pipe from the street. In the circuit breaker box the Neutral buss was bonded to the Ground buss. That was okay. I also checked the sub panel to make sure the Ground buss and Neutral buss were not connected.

The wire mains from the electrical meter are aluminum. Current will find the least path of resistance, therefore current leakage to the piping is occurring. The remedy for this is to drive a conductive rod into the ground as deep as local code requires and connect a ground wire. Additionally I moved the ground clamp to the incoming side of the water meter, and removed the grounding jumper. As the water meter has dielectric connections the leakage can not return into the water piping since it is no longer grounded.

Bert Cooper
Equipment Designer - Williamsport, Pennsylvania

June 11, 2010

Q.Type K soft copper pinholes. We are having numerous issues with 3/4" and 1" and even a couple 2" services running from the mainline in the street to the property. 10 years ago or so we started having pinhole leaks appear on the copper always next to a flaired fitting so naturally everyone blamed it on a bad flair, then the specs changed and we were allowed to use compression fittings. This is now happening with the compression fittings as well, now everyone is blaming it on not de-burring the copper properly.

We just had to dig up a leak and found the pinhole leak in the middle of the 1" copper run (no fittings even close) and the copper was in a 4" sleeve under a major street which would eliminate the corrosive soil theory which the supplier will want to use, also the leak was on the top of the copper so a rubbing situation is not the answer. I have a question, is it possible for the copper at the time of production to have impurities introduced causing an electrolysis situation? Do you know of any other town having this problem. The suppliers here have no idea and have never even heard of this problem before which I find hard to believe. Thank you for your time and opinion

Bill Williams
water company - Tucson, Arizona
September 9, 2010

Q.I have recently installed and new water softener with an aerater in my home. My home is 26 years old and several weeks after the installation I noticed a blueish/green tint. I have had the water tested and the copper level is high, can the new system cause this?

Rachele Cancia
home owner -Sunrise, Florida
November 26, 2010

Q.I had an odd situation and was wondering if there is a known reason.
Last evening we noticed water dripping from the ceiling. Upon cutting open the ceiling, I noticed that the 3/4 hot water heating pipe (not sure if supply or return) was pressing firmly against the 1/2 hot water supply pipe, and that a leak had developed in the (smaller) hot water pipe where they touched. Fortunately, the heating pipe was connected to flexible copper to go up through the floor, and I was able to push the pipes apart and repair the supply line easily, but I am concerned what might have caused this leak.

Mike Paulson
former kitchen contractor, retired -falls church, Virginia

December 17, 2010

Below is an excerpt from Wikipedia's "Tap Water" page at en.wikipedia.org/wiki/Tap_water

"Pin-hole leaks can occur anytime copper piping is improperly grounded and/or bonded; nonmetal piping, such as Pex or PVC, does not suffer from this problem. The phenomenon is known technically as stray current corrosion or electrolytic pitting. Pin-holing due to poor grounding or poor bonding occurs typically in homes where the original plumbing has been modified; homeowners may find a new plastic water filtration device or plastic repair union has interrupted the water pipe's electrical continuity to ground when they start seeing pinhole water leaks after a recent install. Damage occurs rapidly, usually being seen about six months after the ground interruption."

Q.So if I understand this correctly, adding a union may cause this problem? How does one connect copper pipe to galvanized steel then, or how to bond from copper pipe (cold water line, for example) to iron pipe (gas line, for example)? What materials is the bond conductor made of?

Andy Roberts
-Maynard, Massachusetts

May 13, 2011

A.I have seen electrolysis occur with galv. steel straps, hangers and supports, with copper. It usually occurs at the point.
Pin Hole leaks are mostly caused by incorrect installation of plumbing pipes.
For example, If a plumber uses a pipe cutter, to cut a pipe, it leaves a ridge on the inside of the pipe. This causes a ripple in the flow of water going through the pipe, and will eventually start eating away at the pipe, from the inside out. This was a common occurrence back when track homes were booming, and the track rats were doing high volume production, and not installing correctly.
You can verify this, by separating the pipes at the soldered joint, and stick you finger in the pipe and feel the edge. If you feel a sharp edge, then the fitter never filed the inside edge to remove this. Which this is why it will happen in multiple places in your home. Also the reason it happens more to cold water lines, is because you use your cold water more that your hot.

Keith Van Aalst

-Anaheim California


February 3, 2012 -- this entry appended to this thread by editor in lieu of spawning a duplicative thread

Q.I need to run natural gas to an outside heater. I have a 3/4" gal water line which is no longer used, am hoping to run type 'L' flex 1/2" copper line thru this line to supply gas to out side heater, is that possible or is there something I could wrap the copper with to make it work?

Bob Hendrickson
-Pontiac, Illinois, USA
February 25, 2012

Q.I have a bunch of copper fittings. 1/2", 3/4" & 1"; I had the fittings for a year or more. Some of the fittings are starting to get corrosion on them, a greenish thick coating. What is causing this and how do I control/stop it. All the fittings are new and never used.

Ken Kramlich
-Sacramento, California, USA
February 27, 2012

A.Hi, Ken.

Copper corrodes, but usually not that quickly. The simplest fix is probably to put them in a plastic bag with desiccant. Sodium benzotriazole is a copper preservative. You can use brass lacquer if you are trying to protect them for artistic rather than functional use. Good luck.

Regards,

Ted Mooney, finishing.com
Teds signature
Ted Mooney, P.E. RET
finishing.com
Pine Beach, New Jersey

December 18, 2012

A. After reading all of the postings about plumbing -
There are a lot of factors to touch on.

Any type of pipe can be connected to a different type of pipe with the right connectors that can be found at big box or good hardware store.

The green spots inside or outside of a copper pipe is cause by Flux.
Flux is an acid that is used by plumbers when the copper piped is fitted together and soldered.
When a plumber puts too much flux on the copper fittings or pipe - It stays inside the pipe and causes the pipe and or fittings to corrode because the water does not get hot enough to melt flux in order to get it flushed out of the pipe or fittings.
Even if you air pressure out the lines, all of the flux will not move out of the copper pipe because flux is a paste, and what little amount of flux that does move will stick to any joining type of Copper or Plastic or PVC or Galvanized pipe or fittings.
Green spots on the outside of a copper pipe or fittings usually means the plumber did not wipe off any left over flux on the out side of the copper pipe or fittings, or the copper pipe has started to corrode from the inside out from using too much flux inside the pipe and the flux has made its way to the outside of the copper pipe or fittings and needs to be replaced.

As far as electric or electric ground going through copper - Electricity will slowly soften up the excess flux that was used on the copper pipe or fittings.
As the flux softens, and because Flux is an acid, it will slowly break down the copper pipe or fittings and needs to be replaced.

NOTE:
Most electric or electric ground going through a copper pipe is not a high enough voltage to melt flux -- it will only soften the flux.

NOTE:
If your phone line is grounded to the copper line then this alone is enough to soften the flux.
If you put some flux on both the neg. and pos. post of a small charged 9 volt battery you will find that the flux will soften.
If you leave the flux on the battery the flux will corrode the battery because flux is an acid.

NOTE:
If your phone or cable is grounded to your copper pipe this is enough electric for a person to get a small shock when touching the copper pipe.
After a person touches the pipe and gets a small shock, it takes quite a while for the electric to build back up because the voltage is quite low.
It is because the voltage is so low that when a person touches a copper pipe and gets a small shock you have depleted the electric in the copper pipe and a shock will not happen again until the electric builds back up in the copper pipe.

NOTE:
Anytime you have to run a copper pipe behind a wall that will be closed in, only use HARD copper pipe (NOT ROLLED TUBING OR SOFT TUBING). Place the copper pipe inside of a piece of PVC pipe and do not have any fittings or couplings that have been soldered inside the PVC pipe.
If you need to soldier on fittings - Solder the fittings on after you have cleared the wall that will be closed in. It will also be helpful to use liquid foam between the copper pipe and the PVC pipe to stop any pipes from clanking when the water is turned on or off. You can pre make up the pipe with the foam in order to let the liquid foam set up.

I hope this information is helpful.

Jim Drake
- Fredericksburg, Virginia, USA

April 20, 2013

A.To those dismissing the "green blobs" as residual flux are not understanding what I think are the inquisitors' issues. We built our home in 2004 and within a couple of years we started experiencing problems in our master shower. Initially, I was able to disassemble the hot water supply in the manifolds and clear out the green "blobbish" crystals. Our master shower is large and has multiple shower heads and two shower manifolds. Since then the problem appear to only exist in the master bath "hot" water lines. I have never had any issue with the cold water lines.

To give a little more detail. The green blobs I am experiencing a hard crystals and not any type of pasty or flux consistency. I have found galvanized steel nipples between the copper supply lines and the brass shower fittings. Two years ago the galvanized nipple on the shower with the most serious blockage, had nearly corroded away completely. Fortunately I had decided inspect the inside of the shower wall after suspecting some sort of "electronic" cause. This morning I found the same union on the second shower head that is now almost completely blocked.

I should have recognized something was wrong in the construction of our plumbing lines during the build simply because of the sloppy solder joints. I have a rudimentary knowledge of plumbing as my father was a plumber. Unfortunately, I was traveling extensively and didn't have time to address the bootleg plumbers my builder contracted.
I guess I was depending on the inspectors to alert us of any issues, but I have learned that lesson.

In summary, I would conclude that the green crystals are formed from kind electric current activity in addition to the hardness of your water. Our municipal water is very hard and my water softener is worthless so we are going to rip out the bathroom walls to see what other surprises we have in store and get a new water softening system.

Vaughn Broadnax
- Carmel, Indiana, USA

copper pipe secured with metal straps
May 21, 2013

Q.During a bathroom remodel, the plumber used some metal strapping (likely galvanized steel)to further secure the copper piping from the shower valve to the shower outlet. (see photo) Days later, my contractor had secured a loose toilet supply valve with a plastic part and explained that a metal material could negatively interact with the copper and eventually cause a leak. (I think he himself had just come upon this info when he went to home depot to pick-up the part.)
I then remembered seeing how the plumber used the metal strapping to basically tie back the copper piping. The wall has since been scratch coated and is about to be floated. I've alerted my contractor about this and am awaiting a reply. I really do not want the float to happen until I know for sure that there is definitely no problem with the set-up, or, until it is corrected. Any input on this would greatly be appreciated.

Jack Goldstein
- Mission Viejo, California, USA

May 22, 2013

A.Hi Jack. You need 3 things for galvanic corrosion:
- dissimilar metals so there is an inherent voltage between them,
- metallic contact path between the two metals so that electrons can flow from one metal to the other,
- a moist and conductive ionic path so that positively charged ions can follow the electrons, transporting atoms of metal from one point to another.

You certainly have the first two, but whether the third condition is met well enough for serious concern is always the question, and sometimes hard to define. When such a condition is sealed behind a wall, it sounds to me like poor practice -- then again, I'm not a plumber. You might see if you can find anything in the plumbing code about it. The problem would have been easy to avoid with any kind of plastic between the pipe and strap; you can hopefully get a scrap of Visqueen in between them without much damage to the wall. Good luck.

Regards,

Ted Mooney, finishing.com
Teds signature
Ted Mooney, P.E. RET
finishing.com
Pine Beach, New Jersey

June 3, 2013

Q.Having pin hole issues on the cold water line repeatedly over approx. 8 years -- same area.
The house used to have copper pipe coming in from the street and we did not have a ground strap on it. I can see how the pin holes would happen then. Then the copper pipe was replaced with PVC out to the street so there seemed to be no need for the ground on the street side of the meter, but I left the ground connected on the house side (still copper here). Was this wrong? Still another pin hole problem this year.
Tired of water leaks, Tom

Tom Canarecci
- Mishawaka, Indiana, USA
July 11, 2013

Q.We have an apartment building that keeps getting leaks in the first apartment. I have read everything and understand the problem, but we don't have money to replace all the pipes, so every few months there is a leak. The last time we had to replace all the carpet because it was leaking over a full weekend.

I have been told by one plumber that he heard of a product that can be put in the pipes that would coat the insides and help prevent the pinholes from developing.
Is there any such product?

Also someone told me of a product that can be painted on the pipes like a silicone or latex component that might be able to help.

If you know of any products like this that I can try, please let me know.

Thank you.

Lisa Keylon
- Fountain Valley, California, USA
February 11, 2016

Q. I just noticed there is corrosion at the elbo 90 connector of hot water copper pipe going out of water heater. Both are copper pipes - so wondering what's causing the corrosion. Otherwise I'm planning to
Simply planning to use fix-it stick/Keeny pipe wrap tape as temporary fix until I get time to call plumber to cut the pipe and rejoin.
Please advise:
1) is it ok to fix temporarily
2) if I need to dig in further to find the cause before I fix it.
3) are there any other things I need to check / replace while I'm fixing it.
Btw- this is house is 10 yrs old.

Venu Reddy
- Waukee, Iowa

April 8, 2016

A. You can also use a brass nipple between copper and galvanize .

Rodolfo ruiz
- Pasadena California usa
April 2016

thumbs up signThanks, Rudolfo. Yes, you can use a brass nipple between them ... but I don't think it will do much towards stopping galvanic corrosion.

Regards,

pic of Ted Mooney
Ted Mooney, P.E. RET
finishing.com
Pine Beach, New Jersey
Striving to live "Aloha"

This public forum has 60,000 threads. If your question seems off topic to this thread, you might prefer to search the site:


Disclaimer: It's not possible to diagnose a finishing problem or the hazards of an operation via these pages. All information presented is for general reference and does not represent a professional opinion nor the policy of an author's employer. The internet is largely anonymous & unvetted; some names may be fictitious and some recommendations may be deliberately harmful.

Friday, September 15, 2017

Beneteau First 50 - MySailing.com.au

Read article : Beneteau First 50 - MySailing.com.au

Beneteau's latest cruiser/racer is from super-yacht specialist Philippe Briand, by Vanessa Dudley.

FIRST of all, it's not a Farr boat. French boat builder Beneteau has had a golden run with its First line of production cruiser/racers bearing the Farr Yacht Design name, most notably with the First 40.7 and more recently the 47.7, 44.7 and 36.7.
For its new First 50-footer, however, Beneteau turned to Philippe Briand, the French naval architect whose focus in recent years has been on super-maxis like the 140ft Mari Cha IV. Briand advances the proposition that "the primary function of a yacht is to be aesthetic. Her owner has to be proud of her?.

"Philippe Briand was brought onboard to produce a beautiful boat," says John Cowpe of the Australian Beneteau importer, Vicsail. While smaller First models like the 44.7 and 34.7 have been aimed at IRC racing, the new First 50 has a different primary focus, Cowpe says. "It's a sports cruiser, a boat you would race in Premier Cruising division rather than against the IRC class boats like the Cookson 50s."

The result is a stylish and well-proportioned yacht which has some interesting signature features like the "eyebrows" (or eyelids) over the side windows in the coach house (giving the boat a distinctive look, while also providing protection so the windows can be left open while sailing in moderate conditions), and the long bank of green tinted skylight hatches along the centreline both ahead and behind the mast.

It is a much sleeker craft than Beneteau's other current model 50 in the Oceanis cruising range.

In fact it probably has more in common with semi-custom craft such as the Marten 49 in the modern performance/sports cruiser category. With its carbon composite construction the Marten offers higher performance, but at a considerably higher price.

The first boat to arrive in Australia is Playstation 3, for Sydney yachtsman Dean Harrigan, stepping towards a more performance oriented boat from his previous Beneteau 53f5 Big Kahuna, and Greg Hargraves.

Playstation 3 attracted a great deal of interest at the Sydney International Boat Show in August before whisking away for the delivery north to the Audi Hamilton Island Race Week, where it was to compete in the Premier IRC division.

By the time this review is published, there will be racing results on the board for the new boat, which at the time of writing did not yet have an IRC rating.

Rig and deck layout

Playstation 3 is fitted with a black-painted aluminium mast produced by Sparcraft; keel-stepped and tapered with triple aft-swept (20 degree) spreaders. A slightly taller carbon mast, weighing roughly 100kg less, is a more expensive option. The large section aluminium boom is also from Sparcraft.

"A lot has been learned from racing boats to produce a simple boat that works," says John Cowpe. The mainsheet trims on an electric-powered winch on a central island base with no traveller, relying on vang sheeting. There are Navtec hydraulic controls for the vang and the backstay.

Harken winches are used with a 53.2 self-tailer for the main, 60.2 self-tailers for the primaries and four 48.2s on the coach house for the halyards and control lines.

Standard running rigging includes Dyneema halyards and control lines leading back to jammers on the coach roof within reach of the cockpit. Where possible lines are recessed into the deck to provide less cluttered space.
The headsail has a fixed genoa furler under the foredeck. The anchor locker houses a tilting bow roller fitting for the 24kg Delta anchor. A hydraulic ram controls anchor launching on the pivoting arm, which turns through 180 degrees, and there is a 12 volt 1500 watt electric windlass. A separate sail locker with its own access hatch is also located at the bow.
The electronic instruments on Playstation 3 are from B&G, which also supplied an autopilot. This makes the steering a little heavier than would otherwise be the case, but will be a boon for deliveries and cruising.

The standard boat comes with teak cockpit seats, but Playstation 3 was also given a full teak decking job by Vicsail's after-sales team. This added an estimated 80-110kg of weight; "one big guy spread across the whole boat, so it?s not a big issue," says John Cowpe.

The two steering wheels are 900mm diameter painted aluminium. The transom folds down by simply releasing a barrel bolt to provide a boarding and swim platform. The aft section of the cockpit houses a large locker for the life raft or tender, safety gear, etc, and there is a lot more storage in the cockpit seat lockers.

Playstation 3 is set up with a cockpit lighting system of blue LEDs on the boom in front of the mainsheet so "doing a race like the Pittwater to Coffs, the crew can see without blinding the helm," says John Cowpe.

Below decks

The First 50 interior is very much in keeping with the latest styling across the major production yacht builders, including the use of light oak coloured timber, open floor spaces and those raised, square hand basins which are everywhere these days.

The first time I saw this styling ? Japanese influenced to my eye ? was on the German Hanse range, although I'm not sure if that's where it originated.

Stepping down the companionway brings you into a large, light and airy saloon, with a lot of headroom (1.95 to 2.01m) in spite of the relatively low-slung proportions of the coach roof.

The row of green tinted hatches in the centre of the coach roof can be sealed off with blinds and provides a healthy amount of light. According to Beneteau there are in fact 24 opening ports and hatches when you count up all the Lewmar windows with their anodised aluminium frames and include the sliding companionway hatch.

Halogen lighting and articulating reading lamps are included in the standard fit out.

The layout provides three private double cabins, the forward cabin having an en suite bathroom with a separate shower stall, while the mirror-image aft cabins are served by a smaller bathroom on the port side of the companionway. The forward toilet has an 80lt holding tank.

The two aft cabins have innovative soft fabric zip-up hanging lockers on stainless steel frames, while the front cabin has a more conventional full height locker. There is plenty of attention to detail throughout this craft, such as the internal light which comes on automatically when you open this forward locker.

Other details include a dedicated holding area for the stormboards behind the companionway steps, and drawers within drawers in the galley, which is on the starboard side at the aft end of the saloon.

The galley facilities include a 60lt top-opening icebox with a 12 volt evaporative cooling system, plus there is a 100lt fridge, as well as an LP gas oven and stove and quite a lot of storage compartments and bench space.

The L-shaped settee on the port side flanks a timber table on stainless steel legs, while there are two more removable/reversible seats on the centreline. Opposite to starboard is another settee, while outboard on both sides are banks of cupboards with upward opening doors.

Aft of the dining area is a generously sized navigation station with swivel chair, chart table, electrics panel and space to mount nav instruments, radios, etc. An aft-facing desk area can accommodate a laptop computer. The radio/CD/MP3 player is included in the standard equipment list with two saloons and two outside speakers.

Instead of having large floorboards which can be difficult to manage, the First 50 has small laminated timber squares which are lifted individually using a suction cap. This allows access to the bilge and inclusions such as the wine rack housed under the floorboards adjacent to the front of the galley.

The Yanmar 55hp engine under the companionway has an 80Amp alternator attached and a 40Amp battery charger. The 12 volt batteries include a 110 Amp engine starting battery plus two 140 Amp house batteries and there is 220V shore supply with a circuit breaker, and seven 220 volt sockets around the cabins.

Performance

By the time this test is published, Playstation 3 will have some runs on the board from the Audi Hamilton Island Race Week. We did not race the boat, but sailed her in a 5-12kt westerly breeze on Sydney Harbour in flat water.
She is a big, powerful performer, with the T-profile torpedo bulb keel providing a reassuring amount of righting moment when pressed.

In bumpy water you would not expect her to equal the performance of boats like the carbon hulled Marten 49, but her IRC rating should reflect that difference, and in flat water she achieved impressive numbers upwind and reaching without using her new suit of Norths 3DL sails or a spinnaker, which will be flown conventionally from a pole rather than a bowsprit.

Beneteau clearly sees a future in the sports/performance cruiser concept, as the company will release a First 45, also designed by Philippe Briand and similar to the 50 with stylish lines, twin wheels and an open transom, at this year's Paris Boat Show in December.

Specifications

Length overall ... .. .. 14.98m
Waterline length ... ... .. 14.65m
Beam ... ... ... 4.37m
Draft (deep draft option)... 2.80m
Displacement ... ... ... 13,780kg
Ballast ... .. ... 4300kg
Sail area:
Mainsail.............. 68.60sq m
Genoa.............. 70.10sq m
Spinnaker.......... 160sq m
Construction: Solid GRP hull, reinforced by longitudinals and local reinforcements in high load areas, with structural inner hull and deck mouldings bonded and laminated into place. Infusion moulded deck of sandwich GRP/balsa/polyester resin. Mixed lead/cast iron keel with lead and antimony bulb and hollow keel fin, fixed to the hull using stainless steel bolts and backing plates. Composite rudder of GRP/foam with rudder stock of biaxial and unidirectional cloth.
Fuel capacity......................237lt
Water capacity....................................568lt
Engine..........................................Yanmar 75hp marine diesel sail drive with three-bladed folding propeller
Base price: $756,000 ex sails & instruments; $925,000 as tested
Designer: Philippe Briand
Builder: Chantiers Beneteau, Saint-Hilaire-de-Riez, France, www.beneteau.com.
Australian distributor: Vicsail, Rushcutters Bay, NSW. Tel (02) 9327 2088; or visit www.vicsail.com 

Tuesday, February 28, 2017

High Tech Bathroom Faucets for Digital and Electronic Upgrades

Read article : High Tech Bathroom Faucets for Digital and Electronic Upgrades

The easiest way to upgrade your modern bathroom can be installing a new high tech bathroom faucet, and with today’s innovative technologies many digital and electronic faucets are available to the home owners. Whether it’s a sink faucet or a bidet mixer, there are plenty of high-tech ideas to choose from. If you’re remodeling, we want you to be aware of what’s available now. Read on for the coolest upgrades and sources.

<a href=high tech bathroom faucet noken mood High Tech Bathroom Faucets for Digital and Electronic Upgrades" src="http://cdn.trendir.com/wp-content/uploads/old/archives/2015/08/27/high-tech-bathroom-faucet-noken-mood.jpg" width="630" height="501" class="mt-image-none" />

The high tech bathroom faucet Mood by Noken (above) is a digital sink faucet that comes with a display showing temperature and flow rate. It allows to set programs for teeth brushing, face and hands washing, as well as limits on temperature and flow. It has to be plugged in via a 9V transformer (included), and there is also a battery back-up.

noken mood bathroom collection <a href=High Tech Bathroom Faucets for Digital and Electronic Upgrades" src="http://cdn.trendir.com/wp-content/uploads/old/archives/2015/08/27/noken-mood-bathroom-collection.jpg" width="630" height="472" class="mt-image-none" />

This faucet (above) is a pat of the Mood collection, a new modular bathroom concept that includes sinks and toilets integrated with mirrors, faucets and other bathroom accessories.

high-tech-wall-mount-bathroom-faucet-noken-mood.jpg

The digital display with electronic controls (above) enables the water flow and temperature to be customized for each use and user needs. Noken.

bathroom-faucet-with-sliding-temperature-control-cea-regolo.jpg

A bathroom faucet with a sliding temperature control – Regolo by CEA Designs. Not digital but no less cool, one slider controls both the water temperature and the flow.

wall-mount-bathroom-faucet-with-sliding-temperature-control-cea.jpg

This creative faucet (above) works with either horizontal or vertical installation. Just move the slider right and left or up and down. CEA Designs.

high-tech-bathroom-faucet-hansalatrava-electronic-basin-mixer.jpg

For those looking for modern aesthetics and trendy upgrade ideas, there is HansaLatrava, a high-tech bathroom faucet from Hansa (above). This electronic basin mixer creates a luxurious water experience with a fine water “curtain” achieved through the specially developed jet. Photographs by Octopus Design, the designers of this faucet.

hansalatrava-electronic-controls.jpg

An integrated control panel with two electronic push-buttons, one to turn it on and off and another to adjust water temperature with the visual help of a LED indicator. Power supply is included by Hansa.

touch-free-bathroom-waterfall-faucet-hansamurano-x.jpg

This is totally high tech (above) – the HansaMurano X is a touch-free bathroom faucet activated by an infrared motion sensor that not only turns the water on and off but also senses when someone is approaching and turns on the light, presenting the sink with a pretty glow. The top surface also boasts two sensor buttons to set the temperature.

touch-free-bathroom-waterfall-faucet-hansamurano-x-1.jpg

HansaMurano X was designed for Hansa by Bruno Sacco, a former chief designer at Daimler-Benz.

touch-free-bathroom-waterfall-faucet-hansamurano-x-2.jpg

It’s also a waterfall faucet. “Water pours into sink in a broad but wafer-thin laminar spray, while the fine water curtain is created by a special jet former”. A glass layer is sandwiched between the two chrome plates, giving the faucet its characteristic look. Hansa.

black-bathroom-sink-faucet-ametis-graff.jpg

For the ultra-modern high-tech upgrades, there is this cool bathroom faucet collection Ametis from Graff. It includes a vessel sink faucet, a countertop sink faucet, a wall-mounted sink faucet and a bidet faucet, all in single-lever design, and in 3 finishes – polished chrome, black, and white.

electronic-wall-mount-bathroom-faucet-ametis-graff.jpg

The lever on / off handle is a modern touch that maintains the sleek, slender lines of the faucet. A LED light ring around the lever indicates water temperature changes. Graff Faucets.

led-wall-mount-bathroom-faucet-white-ametis-graff.jpg

LED lights turn from blue to red and vice versa as the water temperature changes. A fluid design form with a sleek curve sets the Ametis faucets apart from the rest.

black-countertop-bathroom-faucet-ametis-graff.jpg

This matte black countertop faucet (above) would be a great fit for an ultra modern bathroom.

electronic-bathroom-faucet-nomos-f4101-fima-carlo-frattini.jpg

Above is the electronic bathroom faucet Nomos F4101 from Fima Carlo Frattini. Wow, it looks very high tech, and it can do a lot. Using the touchscreen display, Nomos allows you to regulate the water flow rate and water temperature, program your personal settings and check your water consumption. In addition, there is an on-screen comfort button that offers water at 38°C in an instant. The faucet will also sound alarm if something isn’t working right.

electronic-washbasin-mixer-tap-nomos-f4102-fima-carlo-frattini.jpg

Nomos F4102 electronic sink faucet (above) has a pivoting spout, otherwise it offers the same features as F4101.

electronic-bidet-faucet-with-swivel-spout-novos-go-f4112-fima.jpg
electronic-lavatory-faucet-with-swivel-spout-novos-go-f4111-fima.jpg

Two more faucets (above) from Fima Carlo Frattini with the same electronic touch-screen but in a more classic contemporary design and with a swivel spout – the bidet mixer Nomos GO F4112 and the lavatory mixer Nomos GO F4111.

grohe-veris-f-digital-sink-faucet.jpg

Grohe has two digital bathroom faucets to offer with the same high tech wireless functionality: Grohe Veris F-Digital (above) and Grohe Allure F-Digital (below). These are some of the coolest faucets available on the market today as they are operated by a wireless Digital Controller that can be placed anywhere around the faucet.

grohe-allure-f-digital-sink-faucet.jpg

The minimalist Grohe Allure F-digital sink faucet. The circular control has a square base plate to match the faucet design.

grohe-f-digital-wireless-controller.jpg

Grohe F-digital wireless Digital Controller changes its LED color from blue to red as temperature gets adjusted.
The On/Off button lets you start or stop the water, the Plus/Minus buttons let you adjust the temperature, and the Outside Dial lets you control the water flow by rotating it. The LED illuminated ring gives you instant visual feedback of the water temperature, and a memory function lets you memorize your preferred settings.

grohe-veris-f-digital-basin-mixer-with-wireless-control.jpg

Two modern Grohe Veris F-Digital faucets installed on a double-sink vanity, with two wireless controllers placed side by side.

grohe-veris-f-digital-wall-mount-basin-faucet.jpg

Grohe Veris F-digital wall-mount basin faucet with digital controller attached to natural stone.

grohe-veris-f-digital-bidet-faucet.jpg

Grohe Veris F-digital bidet faucet with digital controller (above).

kwc-ono-touch-light-pro-electronic-faucet-deck-mount.jpg

The KWC ONO touch light PRO bathroom faucet (above) comes in multiple high-tech designs, suitable for a deck-mount or a wall-mount installation. This is not an ordinary faucet which is quite expected from KWC. For greater installation flexibility, it consists of three independent components – a spout, a programmable electronic control and a mixer valve – all three mounted each at its own location as found convenient.

kwc-ono-touch-light-pro-electronic-faucet-wall-mount.jpg

The KWC ONO touch light PRO wall-mount sink faucet and its electronic touch control installed on the same plate.

kwc-ono-pro-electronic-touch-control.jpg

Above is the KWC ONO touch light PRO electronic control, with two LED lighted rings. Tap briefly once for cold water (blue), twice for warm (orange) or three times for hot water (red), to call up the pre-defined settings. To set your preferred temperature, simply turn the control. To regulate flow, press and turn the control. To memorize your own settings, press the control and hold it down until the light ring shines purple.
There is also an option for a wireless control unit that can be placed anywhere in the room.

blok-electronic-faucet-shelf-combo-treemme.jpg

BLOK Electronic faucet from Treemme (above) is an interesting combination of an unusual faucet design and an electronic temperature indicator.

blok-electronic-faucet-shelf-combo-treemme-1.jpg

The glowing LED-illuminated ring is embedded within the spout, so you can monitor temperature of the water with ease. This attractive and useful feature adds a futuristic edge!

blok-electronic-faucet-shelf-combo-treemme-2.jpg

Faucet integrated into a shelf, Blok is a high tech bathroom solution that is very pleasing on the eye and useful at the same time. Treemme.

grohe-ondus-digital-basin-mixer-wall-mount.jpg

Grohe Ondus Digital bathroom faucet (above) is a part of the Grohe Ondus Faucet collection and is in a class of its own.

grohe-ondus-digital-basin-mixer-deck-mount.jpg

There are three electronic control options: either an integrated one (with a digital display, also integrated), as shown above, or an external wireless panel or both. Back-lit icons on the touch control make it look high-tech. And of course, the coolest feature – a back-lit digital display that shows temperature in large digits – adds to the futuristic look. For a complete list of exiting features, visit Grohe.

grohe-ondus-digital-electronic-sink-faucets.jpg

For a bathroom sink faucet, there are two designs available – a deck-mount and a wall-mount. And the deck-mount version can be purchased with an integrated aerator or with the Grohe Ondus flow straightener for a cleaner look (shown). Both designs come in several color combinations including one entirely black for a totally high tech appeal. Grohe.
—
For more ideas on high tech bathroom upgrades, check out our shower head trends as well, and for the latest in all fixtures, check the modern bathroom furniture section.