A combi boiler won't need a tank, I had one in my old flat and it worked well, modern installs these days seem to be back to hot water tanks... Do a search for a combination biller. Cheers
Ian Barkalarr
posted on 15/1/17 at 09:26 AM
It's called a combi boiler. Had one in my old house and took about 45 mins to fill the bath up. That was about 15 years ago - I'm guessing tech has moved on, but not sure if you could run a shower off it ? steve m
posted on 15/1/17 at 09:30 AM
Check that the place has a gas supply first, as it sounds like its an immersion tank, and if theres no gas, then a combi boiler will be a waste of time and money Thats was probably spelt wrong, or had some grammer, that the "grammer police have to have a moan at slingshot2000
posted on 15/1/17 at 09:47 AM
Lots of manufacturers are now offering electric combi-boilers ready for the changes to come in the Building Regs. Lots of advantages over gas. loggyboy
posted on 15/1/17 at 10:16 AM
Also how many bathrooms(inc ensuites/shower rooms)?
Most Combis only cope with 1. There are those who can cope with more, but they still need a cylinder, albeit a lot smaller and usually contained within the boiler or close by, but adds to cost a lot. Will also mean a heavy replumb of house as everything will be mains fed, so needs a good mains feed to start with, or you will get no pressure. [Edited on 15-1-17 by loggyboy] Slimy38
posted on 15/1/17 at 10:38 AM
We've had combi boilers in our house since we moved in. The first one was a cheap unit that barely managed to fill the radiators (previous owners were penny pinchers). When we had an extension built we had one that had much higher capacity (higher than we would need). It's been fine, and can fill a bath very quickly with very hot water while still keeping the radiators warm. The only issue we have is that we wanted it out of the way in the utility, which is the farthest point of the house. Which means any tap needs to run for a few seconds before hot water comes out. That's not a weakness of the boiler, more the fact that there is a fair few metres of cold water in the pipe to get rid of each time. As mentioned ours needs a gas supply and a decent pressure water supply. It wasn't overly expensive, and the whole unit fits in a standard 600mm wall cabinet. Two other points. You can't have it in your bedroom (they spend their days and nights doing random clicks, ticks and 'brums' so you wouldn't get much sleep) so it won't be a direct swap. And we actually miss having an airing cupboard. Our previous house had the immersion tank in a cupboard with shelves round it for storing clothes, and we didn't realise how much we used it. cliftyhanger
posted on 15/1/17 at 11:50 AM
quote:Originally posted by Barkalarr
It's called a combi boiler. Had one in my old house and took about 45 mins to fill the bath up. That was about 15 years ago - I'm guessing tech has moved on, but not sure if you could run a shower off it ? tech won't help. You have just got to get more heat int the water faster. Makes me laugh when the different manufactureres claim better flow rates yet same boiler output, things in reality have changed very little. Just about to run abath from our combi,still takes a while though it is a big old boiler (30kw I think) Back to OP.
If only electric,you can get instantaneous water heaters. Effectively an electric shower unit. Won't be ideal for a bath, but can be fine for showers and washing up etc 02GF74
posted on 15/1/17 at 11:50 AM
already has electric shower, has one bath and two sinks (bathroom and kitchen); not sure if gas is connected hence looking for something electrical that will replace the large immersion heater - another solution would be to fit a much smaller one. Visit China. Meet the child that made your trainers. coyoteboy
posted on 15/1/17 at 11:51 AM
quote:
posted on 15/1/17 at 09:47 AM Lots of manufacturers are now offering electric combi-boilers ready for the changes to come in the Building Regs. Lots of advantages over gas Like what? Apart from electricity being 2-3 times the cost per kwh of heat I can't see much difference. Also, what change in regs? [Edited on 15/1/17 by coyoteboy] Report your local potholes, it actually works! slingshot2000
posted on 15/1/17 at 11:56 AM
Electric combi-boilers have less parts to go wrong, don't require an annual gas check. The government keeps talking about no mains gas supplies to new builds, unless connected to a district heating system. How will you power a gas combi with out mains gas ? mookaloid
posted on 15/1/17 at 12:25 PM
If the property has no gas then the large tank is probably heated overnight using dual rate electric. The idea of a large tank is that you can heat all the water you will need during the day using cheap overnight rates. It probably has a second immersion heater which you can manually switch on to give it a boost if required (at the higher during the day rate) "That thing you're thinking - it wont be that." SteveWalker
posted on 15/1/17 at 12:32 PM
If the shower is electric and you only need hot water for the taps at the sinks, then yes you can buy electric water heaters that sit under the sink or worse looking ones that sit over it - often used for kitchen areas in office buildings. They'll probably mainly be used during peak periods, so will be expensive to run. [Edited on 15/1/17 by SteveWalker] coyoteboy
posted on 15/1/17 at 02:10 PM
quote:Originally posted by slingshot2000
Electric combi-boilers have less parts to go wrong, don't require an annual gas check. The government keeps talking about no mains gas supplies to new builds, unless connected to a district heating system. How will you power a gas combi with out mains gas ? Non-landlords don't need an annual check and I can count the number of boiler failures I've witnessed out of 6private properties on two fingers and < 200 total repair costs. Maybe slightly over playing the concerns there?! Also on new builds maybe, but 99.5% of housing stock isn't new builds, so how does that apply to someone wanting a solution in an existing property? Plus talk is just that. Why would you choose to pay more for heat than you need to for the foreseeable future? [Edited on 15/1/17 by coyoteboy] Report your local potholes, it actually works! slingshot2000
posted on 15/1/17 at 02:24 PM
Ok, a landlord safety inspection isn't required each year in a private property, but an annual service is recommended. I was only suggesting that electric combi-boilers are available as an alternative to gas. Other contributors have suggested using 2 electric immersion heaters plus the new cylinder to suit, how economical would you suggest they are compared to an electric combi-boiler? Manufacturers will not have done all the R&D on electric combi-boilers unless they thought there was going to be a developing market for them.(Edited for a ghastly spelling error) [Edited on 15/1/17 by slingshot2000] coyoteboy
posted on 15/1/17 at 02:29 PM
quote:Originally posted by slingshot2000
Ok, a landlord safety inspection isn't required each year in a private property, but an annual service is recommended. I was only suggesting that electric combi-boilers are available as an alternative to gas. Other contributors have suggested using 2 electric immersion heaters plus the new cylinder to suit, how economical would you suggest they are compared to an electric combi-boiler? Manufacturers will not have done all the R&D on electric combi-boilers unless they thought there was going to be a developing market for them.(Edited for a ghastly spelling error) [Edited on 15/1/17 by slingshot2000] Totally agree, I was just questioning the sanity of the option in any current property that has gas supply. In 10 years when it's becoming enforced on new properties people will have to suck up the massive running cost. Report your local potholes, it actually works! slingshot2000
posted on 15/1/17 at 02:50 PM
. Thanks for that ! 02GF74
posted on 16/1/17 at 06:43 PM
It does have two immersion heater, so ^^^ is spot on. I was originally going to mention thar but didnt think it was significant. All makes sense, seems best option is leave it. Visit China. Meet the child that made your trainers. BangedupTiger
posted on 16/1/17 at 07:04 PM
Interested in these electric combi. How do they rate to conventional Gas combi? Our combi has struggled ever since I installed designer radiators that carry vastly more water. Average size, 5 bed, 3 bathroom. 20 rads. Our biggest issue is cold water pressure is only around 13 lpm. [Edited on 16/1/17 by BangedupTiger]
£45.99 Buy It Now Sold, FREE Shipping, 30-Day Returns
Seller: ourtapscom (19,430)100%, Location:Bournemouth, Ships to: Worldwide, Item:361876195718Condition: New, Type: Bath/ Shower Taps, Mounting:Wall Mounted, MPN: TMC-101, Sub-Type:Thermostatic Mixer, Tap Type:Thermostatic, Brand: OurTaps, Style: Modern, Finish: Chrome, Features: 1/4 Turn Ceramic Disc,Details: WALL-MOUNTED THERMOSTATIC BATH SHOWER MIXER TAPS: Specification & Features: These Thermostatic Bath/Shower Mixer Tap are Wall-mounted. They have a connection for a shower hose just behind the spout outlet and this is controlled by the 'diverter' knob on top of the spout. The spout has a metal mesh filter for smoother water flow. The body is solidly made of brass with a polished Chrome finish. The recommended pressure is between 1 and 5 bar, although they will work at 0.5 bar. Please note... to achieve a water pressure of 0.5 bars with a gravity tank system you need a height drop of some 5 metres (i.e. equates to 0.1 bars per metre). The width of the taps is 28.5cms, the height of main body is 4cms, the depth of the main body is 6cms and the spout reaches some 7cms from the body. The taps come with wall-mounting connections which comprises of two 'S Tails', two Chrome Cover Plates & 2 washers. The distance between the inlet centres at the back of the taps is the UK standard 150mm / 15cms. The left control knob (as you look at the front of the taps) controls the water on/off. The right control knob is the temperature control. This is Thermostatic for comfort and safety, and there is an override stop button set at 38 degrees C. This Valve will work on the following: Combination boiler / Gravity fed / Pumped hot water unvented hot water / Standard hot water cylinder type systems. The maximum unbalanced water pressure ratio is 5:1. Please note that various Shower sets with Handheld Shower Heads, Flexi Hose, and Adjustable Sliding Rail, etc. are available from us. This listing is just for the set of taps. We also sell the deck-mounted version of these taps (ref 057D). Please see our eBay shop.