Showing posts sorted by relevance for query smaller bathrooms Formed. Sort by date Show all posts
Showing posts sorted by relevance for query smaller bathrooms Formed. Sort by date Show all posts

Saturday, March 25, 2017

Modern 1675mm Right Hand L Shape Bath Shower Glass Screen Bathroom Set BL66 • £249.99

Read article : Modern 1675mm Right Hand L Shape Bath Shower Glass Screen Bathroom Set BL66 • £249.99

See Details on eBay

£249.99 Buy It Now Sold, FREE Shipping, 30-Day Returns

Seller: ibathuk (316,627) 98% Top-Rated Plus, Location: GB, Ships to: GB, Item: 331124354685Condition: New, Brand: iBathUK, Material: Acrylic, Length (mm): 1675, Height: 390, Width: 850, Colour: White, MPN: BL66, EAN: Does not apply,Details: iBath UK Need Assistance?Call 02476 389 051 Radiators View All Radiators Radiators Towel Rails Designer Radiators Radiator Valves Radiator Valves Showers View All Showers Shower Sets Shower Sets Shower Accessories Shower Heads Shower Arms Riser Rails Shower Pumps Accessories Bathroom Taps View All Bathroom Taps Basin Taps Modern Basin Taps Traditional Basin Taps Bath Taps Modern Bath Taps Traditional Bath Taps Freestanding Taps Tap Packages Tap Packages Kitchen Taps View All Kitchen Taps Kitchen Taps Chrome Taps Brushed Steel Taps Toilets View All Toilets Toilets Modern Traditional Basins View All Basins Basins Modern Traditional Vanity Units Counter Top Basins Cloackroom Basins Accessories Basin Waste Shower Enclosures View All Shower Enclosures Shower Enclosures Shower Enclosures Bath Screens Bath Screens Shower Trays Shower Trays Bathroom Suites View All Bathroom Suites Bathroom Suites Modern Toilet & Basin Suites Traditional Toilet & Basin Suites Bathroom Furniture Suites Complete Bathroom Suites Complete Bathroom Suites Cloakroom Suites Cloakroom Suites Baths View All Baths Baths Shower Baths Straight Baths Corner Baths Shower Baths L Shape P Shape Freestanding Baths Modern Freestanding Baths Traditional Freestanding Baths Bath Accessories Bath Wastes & Accessories Furniture View All Furniture Vanity Units Combined Toilet & Basin Units Bathroom Furniture Basin Units Gloss White Furniture Cloakroom Furniture Units Bathroom Mirrors Mirror Cabinets Illuminated Mirrors SALE Free Delivery for Mainland UK 10 Year Guarantee UK Based Customer Services No.1 UK Bathroom Seller 1675mm Right Hand L Shape Bath Set Our 1675mm modern L Shape square bath is ideal for a family bathrooms, as it features increased insulation which keeps your bath water hotter for longer, due to the thermal properties of the reinforced acrylic. This shower bath is formed from top class, sanitary grade acrylic and reinforced with a specially formulated glass fibre resin. This bath set includes a right hand L shaped bath and a reinforced glass screen. Ideal space saving solution Formed from sanitary grade acrylic 4mm Reinforced glass screen Warm to touch finish Increased insulation Watch item Ask a Question ANY QUESTIONS? Give our experienced customer teams a call on 02476 389 051 Description Bath Set Features:Large showering area combined with practical bathing area Ideal space saving solution for smaller bathrooms Formed from top class, sanitary grade acrylic 4mm Reinforced glass screen Increased Insulation keeping bath water hotter for longer Warm to touch finish Supplied with leg set Choice of tap positioning – drill to suit Waste not included - available from our eBay Store 10 Year Guarantee Please note: Side and end panels are not included Bath Dimensions: Length: 1675mm Width: 850mm Height: 390mm Screen Dimensions: Depth: 4mm Width: 805mm Height: 1400mmPlease Note: Screen may vary slightly from image Why buy an iBathUK bath?Our Baths have no pre-drilled holes to give a choice of wall or deck mounted tapsOur baths have a 'warm to the touch' finish due to the thermal properties of the quality acrylic that we use.The heavy duty sanitary grade acrylic means that our baths can withstand harsh household chemicals. We go the extra mile and offer a 10 year functionality guarantee and excellent customer service Delivery Returns Terms & Conditions Guarantee Delivery Returns Terms & Conditions Guarantee For the full terms and conditions please click here Delivery Returns Terms & Conditions Guarantee What does this mean for you? In the very unlikely event that one of our products is faulty, you can return it to us for a replacement, up to 10 years after you bought it. As you will no doubt be using your product on a regular basis, overtime it will pick up some signs of wear-and-tear. This warranty will cover you for faults that are due to manufacture. If your item does become faulty... There are a number of reasons why your item might not be working as well as it did when you first bought it. It's very possible we may be able to solve your issue without you have having to return your item. Your first step would be to contact our customer service team via telephone ro the ebay messaging service. We will need images of the product and fault sending over to us so we can analyze the issue and try to solve the problem. If they are unable to solve the problem they will ask you to return the item for an inspection. Once the item is found to be faulty we will arrange for a replacement part to be sent out to you and your delivery charge will be refunded. Exceptions Unfortunately we are unable to offer a 10 year warranty on the bulbs in our LED shower heads or the bulbs in our LED and back lit mirrors. We will cover the product itself, but because of the nature of this product we will not be able to offer a 10 year warranty on the life of the bulbs. Best Sellers ANGLED CHROME TOWEL RAD RAIL RADIATOR VALVES TAPS V01A £7.49 View item Modern Bathroom Mixer Shower Square or Round Chrome Thermostatic Twin Head Set £56.99 View item Chrome Straight Heated Bathroom Towel Rail Rad Radiator - FREE 10 Year Guarantee £23.99£47.99 View item Pop Up Basin Waste ( Bathroom Chrome Sink Push Button Click Clack Plug ) TW04 £5.69 View item STRAIGHT CHROME TOWEL RAIL RADIATOR VALVES TAP RA01S £7.49 View item Vertical Flat Panel Column Designer Bathroom Radiators White Anthracite £48.99 View item Modern Gladstone Bathroom Sink Taps Bath Filler Shower Mixer Chrome Basin Tap £19.99 View item New Modern Chrome Waterfall Bath Filler Shower Basin Mixer Tap Bathroom Set £22.77 View item Why Shop With Us? 10 Year Guarantee Flexible Delivery Huge Stock Free Delivery Money Back Guarantee Want The Best Bathroom Deals? Follow the biggest bathroom retailer on eBay. Get the updates from our constant increasing range, our extensive deals and the amazing prices first hand Follow us! You don't want to miss out! Further Information About Us Contact Us Delivery Returns Terms & Conditions

  •  Popularity - Very high amount sold, 14 Sold, 0 Available. N/A Views, Listed 1,334 days ago.
 Price -  Seller - Over 316,627 items sold. 2% negative feedback. Top-Rated Plus! Top-Rated Seller, 30-day return policy, ships in 1 business day with tracking. Over 316,627 items sold. 2% negative feedback. Top-Rated Plus! Top-Rated Seller, 30-day return policy, ships in 1 business day with tracking. Recent Feedback

Wednesday, September 13, 2017

P Shape Shower Bath 1500 1675 1700mm with Screen Left or Right Hand Bathroom • £209.00

Read article : P Shape Shower Bath 1500 1675 1700mm with Screen Left or Right Hand Bathroom • £209.00

See Details on eBay

£209.00 Buy It Now 26d, FREE Shipping, 30-Day Returns

Seller: bathshop321co (2,739) 98.2%, Location: Heywood, Ships to: GB, Item: 111646484815Condition: New, Sub-Type: Shower Bath, Brand: Synergy, Material: Acrylic, Length (mm): 1500, 1600, 1675, 1700, Features: Shower Screen, Front Panel, Room: Bathroom,Details: [[SALE-TAG]]459[[/SALE-TAG]] eBay by Web Vitality Got A Question? Call 0330 053 6040 SuitesComplete Bathroom SuitesFreestanding SuitesToilet and Basin SetsFurniture SuitesBaths1500mm Baths1600mm Baths1700mm Baths1800mm and Larger BathsCorner BathsFreestanding BathsP Shaped Shower BathsL Shaped Shower BathsDouble Ended BathsWhirlpool Spa BathsStraight BathsToiletsModern ToiletsTraditional Style ToiletsWC PansHidden CisternsClose Coupled ToiletsBack To WallBasinsCompact Sinks / BasinsVanity Sink / Basins1 Tap Hole Sinks / Basins2 Tap Hole Sinks / BasinsCounter Top Sinks / BasinsModern Sinks / BasinsTraditional Sinks / BasinsTapsBath Mixer TapsSink / Basin Mixer TapsShower Bath TapsFloorstanding TapsWaterfall TapsSeparate Hot and Cold TapsShowersComplete ShowersConcealed ShowersShower HeadsBar Valve ShowersRiser Bar ShowersBath/Shower screensShower EnclosuresHeatingHeated Towel RailsRadiatorsAccessoriesBath WastesSink / Basin WastesBathroom AccessoriesMirrorsCabinets Free Delivery When you spend over £500 Best Price Guarantee We beat or match all other retailers Rated Great by We Sell 1,000's of bathrooms every month Next Prev Next Prev Next Prev P Shape Shower Bath 1500 1675 1700mm with Screen Left or Right Hand Bathroom In Stock This item is eligible for free delivery P Shape Bath Panel and Screen This Modern P-shaped bath is a stylish addition to any modern bathroom.If you want your new bath to add more than just the conventional standard baths look no further than this.This bath is a great option for those who can't decide between a bath or a shower as it offers the versatility for you to have both! Made from quality Acrylic with a fibreglass underlay, the bath has an overall thickness of 5mm.It also comes complete with a matching white front panel, fitting kit and Curved 6mm safety glass shower screen allowing you to install this immediately. Features: amazing durability heat retention 5mm thickness front panel included Dimensions: 1500 Bath Length: 1500mm Width: 850mm (750mm narrow end) Height: 550mm 1600 Bath Length: 1600mm Width: 850mm (750mm narrow end) Height: 550mm 1675 Bath Length: 1675mm Width: 850mm (750mm narrow end) Height: 550mm 1700 Bath Length: 1700mm Width: 850mm (750mm narrow end) Height: 550mm Glass Screen: Screen Height: 1400mm Screen Width: 730mm RRP: £459 £209.00 Buy Now Ask a Question Add to Basket Delivery Charges and Exclusions We do NOT deliver to the following: Scottish Islands, Ireland, HS, KW, ZE Scotland, Northern Ireland, Isle of Man, Isle of White, PO30-41£99.99 Mainland UKFree Description Delivery Why Buy From Us? Payment Returns Terms P Shape Bath Panel and Screen This Modern P-shaped bath is a stylish addition to any modern bathroom.If you want your new bath to add more than just the conventional standard baths look no further than this.This bath is a great option for those who can't decide between a bath or a shower as it offers the versatility for you to have both! Made from quality Acrylic with a fibreglass underlay, the bath has an overall thickness of 5mm.It also comes complete with a matching white front panel, fitting kit and Curved 6mm safety glass shower screen allowing you to install this immediately. Features: amazing durability heat retention 5mm thickness front panel included Dimensions: 1500 Bath Length: 1500mm Width: 850mm (750mm narrow end) Height: 550mm 1600 Bath Length: 1600mm Width: 850mm (750mm narrow end) Height: 550mm 1675 Bath Length: 1675mm Width: 850mm (750mm narrow end) Height: 550mm 1700 Bath Length: 1700mm Width: 850mm (750mm narrow end) Height: 550mm Glass Screen: Screen Height: 1400mm Screen Width: 730mm For smaller items such as taps, mirrors, showers and radiators you should expect to receive your delivery no later than 5 working days after placing your order. For larger items please refer to listings for more detailed information regarding deliveries. We use recognised carriers and all deliveries are trackable. Collections, between 10am and 2pm, can be made providing 24 hours notice is given. At Bathshop321 we sell bathroom products at exceptional value for money. Our products are fully supported with manufacturers warranties. All the products are straight from stock and will be despatched to you within a few working days. All the prices quoted on this site include VAT. we hope you find what you are looking for on our website, but if you need any further information please contact us and we will be happy to help. All Auction and "Buy It Now" prices include VAT. Payment must be received within 7 days of auction end. For most items, you have the right to return your goods within 14 working days of receiving them. If you wish to return goods using this right, you need to inform us within 14 working days of receiving the goods. You must take reasonable care of the goods and immediately reurm them at your own expense. We are happy to arrange this for you but the expense will be deducted from any refund. We will not consider that you have taken resonable care of the goods if they have been used in any way, or to an extent beyond what would be reaonable when examining the goods in a shop before purchase. To organise a refund contact customer service via messages . We will respond by giving you a Returns number, which you should include when returning the items to us. Faulty Goods: In the event you receive faulty goods, or a product develops a fault within its warranty period please contact us via messages in the first instance. 1. About these Terms and Conditions These terms and conditions are in place to protect you and Bathshop321.com. Here we detail our commitment to you and provide a few simple guidelines to make your purchase as smooth as possible. Your order constitutes an offer to us to buy a Product or Products and is a binding contract. By purchasing goods from Bathshop321.com you are agreeing to be bound by these terms. 2. How The Contract Is Formed Between You And Us 2.1 After placing an order, you will receive an e-mail from us acknowledging that we have received your order. Please note that this does not mean that your order has been accepted. Your order constitutes as an offer to us to buy our products. All orders are subject to acceptance by us. The contract between yourself and Bathshop321 will only be formed when we dispatch your items. 2.2 The Contract will relate only to those Products we dispatch to you. We will not be obliged to supply any other Products which may have been part of your order until those Products become available to us for dispatch. 3. Your Customer Status By placing an order through our website, you agree that: You are legally capable of entering into binding contracts; and You are placing your order from within the UK 4. Your Consumer Rights 4.1 If you are contracting as a consumer, then subject to clause 4.3, you may cancel a Contract at any time within fourteen working days, beginning on the day after you received the Products. In this case, and in accordance with our returns policy (set out in clauses 10-13 below) you will receive a full refund of the price paid for the Products, but you will be responsible for the cost of returning the Products to us. Please see clauses 10, 11, 12 and 13 for further info. 4.2 To cancel a Contract, you must inform us in writing (preferably email ) You must also return the Products to us immediately, in the same condition in which you received them, and at your own cost and risk. You have a legal obligation to take reasonable care of the Products while they are in your possession. If you fail to comply with this obligation, we may have a right of action against you for compensation. 4.3 You will not have any right to cancel a Contract for the supply of any Products: i) That have been custom made to suit your specifications; ii) Which by reason of their nature cannot be returned; or iii) Which you purchased through our showroom or collection through our warehouse iv) If you have bought the item(s) in a professional capacity in line with your usual business i.e. plumber 4.4 Details of this statutory right, and an explanation of how to exercise it, are provided in the Dispatch Confirmation. This provision does not affect your statutory rights as a consumer. 5. Delivery Procedure and Quality Control 5.1 Deliveries are made by an external professional logistics company. To fulfil your order you will need to provide the courier company with your personal details, name, and address and telephone number. As such please ensure all details are correct and up to date, especially if using PayPal, if you provide us with incorrect details you may incur additional charges. 5.2 You will receive a dispatch notification or confirmation email from us once your product has been sent. If you do not receive this please do not hesitate to contact one of the team 5.3 Smaller items will be delivered without prior notification however if you are not home they will leave a drop note so you can re-arrange delivery or collect the item yourself from the local depot. 5.4 Larger items are sometimes palletized for delivery; the pallet will be delivered as close as possible to your front door. If this location is unreachable for any reason, such as a narrow street, up a flight of stairs (such as flats) or any other obstruction, delivery will be made as near to your property as possible. The driver is not insured to take the goods inside your property. The pallet will be delivered to the location as stated above and it is strongly recommended that at least two able bodied persons are available to receive the delivery and carry the goods inside. Quality Control 5.5 Before any of our products are loaded onto our delivery vehicles and leave our premises to be delivered to you, we undertake a quality control check which consists of a visual examination of the Product and preparation of a Quality Control Report. 5.6 In the unlikely event that you or your servant or agent (including plumber or other installer) discover a defect upon taking delivery of a Product, then not withstanding your rights under clause 9 and 10 below, we require that you notify us as soon as possible, and in any event no later than 7 working days of the date of delivery (or such longer period as we may, in our absolute discretion, otherwise agree to), and before any installation work is undertaken. We will then deal with the Product in accordance with our returns policy for defective products under clause 12 below. 6. Delivery Timescales 6.1 We will attempt to adhere to the below timescales as far as possible but we do not in any way guarantee a delivery date. Any delivery dates or times provided during the checkout process are estimated and are subject to change. Invariably we will contact you to confirm any subsequent changes. 6.2 Smaller items should be delivered within 4 working days after you receive a dispatch notification. 6.3 For larger items our logistics department will contact you (usually within 48hrs after you order to arrange delivery with you). If you miss a prearranged delivery you may be liable for a redelivery charge this is at the courier's discretion. Our priority delivery service will offer you a guaranteed delivery day but please note the courier company will not book in with you. 6.4 If you have not heard from us within 4 days of receiving your order confirmation please contact us and we will assist you in tracking you order. 6.5 Our delivery drivers where possible will always endeavour to phone you and hour before they arrive on site. Please make sure your contact details are correct at the time of placing your order. 7. The 14 Day Money Back Guarantee 7.1 We are confident that you will be delighted with your goods. In the unlikely event that you should wish to return an item to us, we are pleased to offer a 14 day money back guarantee of your full purchase and transaction price, commencing the day after delivery and lasting 14 working days. 7.2 We cannot refund goods that have not been subjected to reasonable care whilst in your possession or that have been or attempted to have been installed or fitted. Refunds will only be issued when goods have been returned and checked by our returns department. 8. Checking Goods for Damage and Notifying Bathshop321 8.1 For small item deliveries that arrive by courier you agree to open all boxes and thoroughly check the goods for damage on the day of delivery and notify us of any damage within a reasonable time. Do not sign for goods that are obviously damaged on receipt, please refuse the delivery. If there are any noticeable damages or faults please let us know as soon as reasonably possible. If we are not notified of damage within 48hrs we are unable to claim from either the manufacturer or the carrier. Your help in this matter is greatly appreciated but not compulsory. This period of 48 hours also in no way affects or changes your statutory rights. 8.2 For bulky deliveries that arrive on pallets you agree to check the condition of the pallet and sign the driver's delivery note only if the items seem in good condition. The courier will wait while the ‘outer black' wrapping is taken off to check for outer damage but this must be completed immediately (the driver is not expected to wait while the pallet is unpacked), if the driver refuses to wait while you do this please refuse the delivery. You agree to open all boxes and thoroughly check the goods for damage on the day of delivery and notify us of any damage within a reasonable time. If we are not notified of damage within 48hrs we are unable to claim from either the manufacturer or the carrier. This period of 48 hours in no way affects or changes your statutory rights. 8.3 If someone else is signing for the goods on your behalf you agree to advise them that the goods must be checked and you accept full responsibility for any loss or damage if they sign on your behalf and fail to check. If the packaging is damaged in any way then please refuse to accept the delivery. 8.4 If you discover your product to be damaged within the time-scales provided above then please follow the procedure detailed in Returns Policy under faulty goods. 9. Returns Policy 9.1 If you need to return a product to us for any of the below reasons you must first complete the Customer Returns & Refunds (Request Via Message). 10. Returns Policy - Changed Your Mind 10.1 Talk to our experts first! – We may be able to work with you to resolve the issue. You are within your right to cancel an order placed with us, up to 14 working days from the date your order is delivered for a full refund. 10.2 If you cancel your order before goods are shipped, then we will refund the delivery cost along with the cost of goods. 10.3 If you decide to return goods after they have been delivered; it is your responsibility to arrange this return at your own cost, we can help coordinate this procedure on request. For large palletised deliveries please be aware that the costs to send them back will be considerably higher than you are charged for delivery. We suggest that you take out carrier insurance because if the goods do not arrive back in re-saleable condition no refund will be made. It is your responsibility to ensure that returned goods reach us in good condition complete with all packaging (please do not write the return address directly on product boxes). 10.4 Refunds will only be issued when goods have been returned and checked by our returns department and processed within 30 days of you giving notice of the cancellation. The products must be returned as new and where applicable in their original packaging. If we arrange the return for you we will pass on the cost and charge you the same fee incurred by Bathshop321 to return the goods. 11. Returns Policy – Incorrect Goods 11.1 By placing an order with us, you agree to check all goods upon arrival and notify us within a reasonable time of the error. 11.2 If you find that the items you have received are incorrect or that there are items missing from the delivery please contact us immediately and we will investigate the problem. If it is found that products are incorrect or missing the situation will be rectified as quickly as possible with no additional charges incurred by you. 12. Returns Policy – Faulty Goods 12.1 Following delivery of the goods it is your responsibility to thoroughly inspect all your items as soon as possible. . 12.2 If you discover your product to be damaged within the timescales of the stated manufacturer's warranty you need to complete the Customer Returns & Refunds Form (Request Via Messages). 12.3 Where possible you may need to provide photographic proof of the damage/fault and this will help us to assess the best course of action. Faulty items will be assessed on a case by case basis we will notify you as soon as practicably possible of the result. We aim to work through this with you. 12.4 If we deem the product to be faulty we will replace it only once the faulty item has been returned. If a replacement item is required before the faulty product can be returned we would need to charge a small deposit which would be refunded on safe receipt of the faulty item. If we choose not to replace the faulty item but instead refund it, we will refund the full item value plus any costs incurred in returning the item too us. 13. Pricing errors and genuine mistakes 13.1 The price of any Products will be quoted on our website, except in cases of obvious error. 13.2 These prices include VAT but exclude delivery costs, which will be added to the total amount due as set out in our Delivery Options. 13.3 Prices are liable to change at any time, but changes will not affect orders in respect of which we have already sent you an Order Confirmation email. 13.4 Our site contains a large number of Products and it is always possible that, despite our best efforts, some of the Products listed on our site may be incorrectly priced or have the incorrect information. Where a Product's correct price is less than our stated price, we will charge the lower amount when dispatching the Product to you. If a Product's correct price is higher than the price stated on our site, we will either contact you for instructions before dispatching the Product, or reject your order and notify you of such rejection. 13.5 If the pricing error is obvious and unmistakeable and could have reasonably been recognised by you as an error, we do not have to provide the Products to you at the incorrect lower price. 13.6 Payment for all Products must be by PayPal, credit and debit card. We accept payment with Visa, MasterCard, Visa Delta, Switch and Maestro. Payment will be debited at time of order through the PayPal Pro Card payment system. 14. Written Communications Applicable laws require that some of the information or communications we send to you should be in writing. When using our site, you accept that communication with us will be mainly electronic. We will contact you by e-mail or provide you with information by posting notices on our website. For contractual purposes, you agree to this electronic means of communication and you acknowledge that all contracts, notices, information and other communications that we provide to you electronically comply with any legal requirement that such communications be in writing. This condition does not affect your statutory rights. 15. Our Liability 15.1 We warrant to you that any Product purchased from us through our site is of satisfactory quality and reasonably fit for all the purposes for which products of that kind are commonly supplied. 15.2 The provisions in clause 15.3 shall only apply if you are contracting as a business and not as a consumer. 15.3 Subject to clause 15.6: a. we shall under no circumstances whatever be liable to you, whether in contract, tort (including negligence), breach of statutory duty, or otherwise, for any loss of profit, or any indirect or consequential loss arising under or in connection with the Contract; and b. our total liability to you in respect of all other losses arising under or in connection with the Contract, whether in contract, tort (including negligence), breach of statutory duty, or otherwise, shall in no circumstances exceed the price of the Products you have purchased. 15.4 If you intend to install a Product you have purchased from us through a plumber or other installer and, prior to the installation, you are aware of a defect as referred to under clause 12, or your plumber or installer should reasonably be expected to discover and therefore become aware of any such defect upon inspection, then if the planned installation proceeds we will not be responsible for any costs of reinstallation, incurred by you or your plumber or other installer, which you may subsequently claim to have been necessary as a result of the defect. 15.5 In the event of us agreeing to reimburse you for the costs of reinstallation (for instance, if we determine that the Product in question was defective when installed but such defect may not have been clearly apparent to you or your plumber or other installer) then such reimbursement is limited to your plumber or other installer's reasonable costs, which may be determined with reference to normal industry levels at the time in question. 15.6 Nothing in these terms and conditions shall limit or exclude our liability for: fraud or fraudulent misrepresentation; death or personal injury caused by our negligence, or the negligence of our employees, agents or subcontractors (as applicable);c. breach of the terms implied by section 12 of the Sale of Goods Act 1979; defective products under the Consumer Protection Act 1987; or any matter in respect of which it would be unlawful for us to exclude or restrict liability. 16. Events outside Our Control 16.1 We will not be liable or responsible for any failure to perform, or delay in performance of, any of our obligations under a Contract that is caused by events outside our reasonable control (Force Majeure Event). 16.2 A Force Majeure Event includes any act, event, non-happening, omission or accident beyond our reasonable control and includes in particular (without limitation) the following: Strikes, lock-outs or other industrial action. Civil commotion, riot, invasion, terrorist attack or threat of terrorist attack, war (whether declared or not) or threat or preparation for war. Fire, explosion, storm, flood, earthquake, subsidence, epidemic or other natural disaster. Impossibility of the use of railways, shipping, aircraft, motor transport or other means of public or private transport. Impossibility of the use of public or private telecommunications networks. The acts, decrees, legislation, regulations or restrictions of any government. Or any other event that constitutes as an act of God 16.3 Our performance under any Contract is deemed to be suspended for the period that the Force Majeure Event continues, and we will have an extension of time for performance for the duration of that period. We will use our reasonable endeavours to bring the Force Majeure Event to a close or to find a solution by which our obligations under the Contract may be performed despite the Force Majeure Event. 17. Waiver 17.1 If we fail or delay, at any time during the term of a Contract, to insist upon strict performance by you of any of your obligations this does not mean we have given up our rights and we may still require you to comply with your obligations under the Contract. 17.2 If we forgive (in writing) any particular default by you of your obligations under a Contract, that does not forgive any subsequent default by you. 18. Severability If any of these terms and conditions or any provisions of a Contract are determined by any competent authority to be invalid, unlawful or unenforceable to any extent, such term, condition or provision will to that extent be severed from the remaining terms, conditions and provisions which will continue to be valid to the fullest extent permitted by law. 19. Entire Agreement 19.1 We intend to rely upon these terms and conditions and any document expressly referred to in them in relation to the subject matter of any Contract. While we accept responsibility for statements and representations made by our duly authorised agents, please make sure you ask for any variations from these terms and conditions to be confirmed in writing. 20. Our Right to Vary These Terms And Conditions 20.1 We have the right to revise and amend these terms and conditions from time to time to reflect changes in market conditions affecting our business, changes in technology, changes in payment methods, changes in relevant laws and regulatory requirements and changes in our system's capabilities. 21. Law And Jurisdiction Contracts for the purchase of Products through our site will be governed by English law. Any dispute arising from, or related to, such Contracts shall be subject to the non-exclusive jurisdiction of the courts of England and Wales. DISCLAIMER: We strongly recommend that you do not book a tradesman until you have received our goods and checked they are in perfect condition. Any modifications of products will invalidate the warranty. We will not be held responsible for any delays in delivery once the item has left our warehouse. Should there be damage to your goods then our liability for losses you suffer as a result of this is strictly limited to the purchase price of the product you purchased. We are not responsible for indirect losses which happen as a side-effect of the main loss or damage and which are not foreseeable by you and us (such as loss of income or revenue, loss of business, loss of profits or contracts, loss of anticipated savings, waste of management or office time). Related Products Prev Next Prev Next Prev Next Delivery Returns FAQs Terms Contact Us-->

 Price -  Seller - Over 2,739 items sold. 1.8% negative feedback. Top-Rated Seller! Ships on time with tracking, 0 problems with past sales. Over 2,739 items sold. 1.8% negative feedback. Top-Rated Seller! Ships on time with tracking, 0 problems with past sales. Recent Feedback

Wednesday, August 9, 2017

5 Bathroom Accessories Guaranteed to Impress your Guests

Read article : 5 Bathroom Accessories Guaranteed to Impress your Guests

The bathroom is upon which all homeowners are judged; if it’s anything less than spotless, shiny and comfortable, guests will throw their noses up in disgust and judge the owner of said bathroom (albeit silently, unless they’re really mean).

Bathroom AccesoriesImage Credit: www.bluehomedecor.com

Therefore, we should probably all pay a little bit more attention to making our bathrooms the best they can be. While for some this might mean tearing up their bathroom and starting again, renovating your bathroom can be as simple as installing one simple yet dazzling centrepiece accessory.

Here are five eye-catching bathroom accessories that are guaranteed to impress your guests.

Waterfall shower

There’s nothing quite like a tepid, low-power shower to dampen the spirits. Waterfall showers negate this problem somewhat, replacing the standard power shower head with a shower head that dispenses water in the manner of a waterfall.

There are two key reasons why a waterfall shower is impressive; the first is that it’s just like showering under a waterfall, which is bound to impress guests. The second is that they’re just so nice to look at – you could probably just leave the shower running and use it a bathroom water feature, if you don’t mind paying the earth in water bills and facing the judgement of environmentalists everywhere.

Heated towel rail

A towel rail isn’t much to look at, but the beauty of the heated towel rail isn’t purely cosmetic. Instead, the beauty of a heated towel rail lies in the experience of emerging from the shower to a crisp, warm towel – especially on a cold morning. Your guests will love you for it, and will probably want to shower at your place every day…

…Until they get their own, of course. Of all the items on this list, heated towel rails are the cheapest and the one accessory I’d consider an essential!

Demister mirrors

Bathroom mirrors tend to lack the opulence of other mirrors in the home, tending to favour function over fashion. A functional accessory can still be impressive, however, as is the case with demister mirrors.

The beauty of demister mirrors lies in their simplicity; using heated pads beneath the surface of the mirror, these mirrors combat the age old problem of a steamed up mirror after a shower. No more wiping the mirror with your hands to get a look at your freshly clean mug! Your guests will love it, and you will too.

Vessel sinks

Sinks aren’t the most impressive of objects, but even the most disinterested of sink sceptics (if such a person exists) would struggle not to be impressed with a vessel sink.

Vessel sinks are essentially mini-bath tubs that sit slightly raised from the surface (or even sit on the surface itself). While you might not find use for that much sink space on a regular basis, the sheer aesthetics of a vessel sink make it a must have for homeowners looking to impress.

Waterfall faucet

The smaller but perfectly-formed cousin of the waterfall shower, waterfall faucets are based on the same concept of making the water that comes from your taps look more natural in its flow. Most waterfall faucets take the form of a small joystick-esque tap in the centre of a chrome circle. This circle is surrounded by a larger class circle. Even if the novelty eventually wears off, a waterfall faucet is worth it for the first time a guest happens across it and wonders ‘what on Earth is that?!’

So those are five bathroom accessories guaranteed to get your guests talking. Got any more suggestions? Leave a comment below.

Chris Smith is a writer currently writing for Illuminated Mirrors. In his spare time, Chris is still failing to finish one of the many DIY projects he started over a year ago.  

Saturday, May 6, 2017

Copper pipe electrolysis from touching galvanized steel?

Read article : Copper pipe electrolysis from touching galvanized steel?
topic 24664

An ongoing discussion from 2003 through 2016 . . .

(2003)electrolysis in copper pipe

Q.I recently had a 1/2" TYPE L HMP flexible copper pipe that sprung a leak, unfortunately it was inside the wall going up to the second floor. After splicing the pipe where it was leaking another spot started leaking. I noticed inside the pipe a bunch of green "blobs" & the outside of this (HOT) water pipe a lot cleaner than the other pipe (COLD) that would have been put in at the same time, 20-25 years ago I'm guessing. I did notice one spot where the copper pipe was touching an old galvanized pipe seemed to be wet and green. Could there have been some electrolysis going on that caused this pipe to start getting finer than pin hole leaks & how much damage might have been done to the rest of the plumbing if that is the case?

THANK YOU FOR YOUR HELP,

Alex H [last name deleted for privacy by Editor]
do-it-myself-er - Cedar Rapids , Iowa

(2003)

A.Copper pipes can corrode in at least three different ways, but the differences are quite technical. I would suggest that the corrosion could be induced by a galvanic couple caused by contact with the galvanised pipe and this results in an induced local anodic polarisation of the copper pipe. I would normally expect such a failure to occur where the two pipes come into contact, but if this point is dry, no corrosion will occur and the effects of the galvanised pipe will be transmitted onto the copper pipe where it will react in a more favourable wet environment. Your photograph clearly shows the green copper salts on the inside of the failed straight pipe, so it must have been in an area where the copper is oxidised and failed. The propensity for copper pipes to fail is related to how the pipe was made, the local water composition and the environment it is used in. I would suggest there may be other not be other problems with your copper pipes, as there has already been a failure of an induced polarity, but if there are other non-compatible pipes in contact with each other, there could be a repeat of this. It may be wise to ask a plumber to check your system out.

trevor crichton
Trevor Crichton
R&D practical scientist
Chesham, Bucks, UK

(2004)

Q.I was told by a local plumber that electrolysis can occur in copper pipes when the hot water heating system is part of a forced hot water boiler system. The solution is to put nylon fittings between the copper connections and the galvanized boiler system so as to prevent any electrolysis action from taking place in the copper pipes running throughout the building. I would like to get other opinions since this is an expensive fix and it takes a long time to determine whether the fix in fact works.

Dan W [last name deleted for privacy by Editor]
property management - Juneau, Alaska

(2004)

A.It is the right advise, Dan. For galvanic corrosion to occur you need a metallic circuit and an electrolyte circuit. If you break the conductive metal circuit between the copper and galvanized pipe, galvanic corrosion ("electrolysis")" does not occur. This is not to say that no form of corrosion will ever occur though.

Ted Mooney, finishing.com
Teds signature
Ted Mooney, P.E. RET
finishing.com
Pine Beach, New Jersey
(2004)

A.Copper pipe failure began to occur approximately eight years after completion of a new home in Brewster Co. Texas. The leaks were always in the cold line.

A split-core ammeter revealed a slight current flow between the steel gas pipe and the hot side of the copper system. No current could be detected between the cold copper pipe and the hot, or the steel gas line. This led me to conclude that the cold line was acting as a sacrificial anode between the other two while absorbing all voltage drop.

No electrical bonding could be found.

My solution was to isolate the steel line (which included some galvanized parts), from the copper system with a PVC adapter.

Current flow cannot now be detected unless a jumper is placed between the steel and copper.

Is the problem solved? I don't know! What can be said is that there is no further measurable evidence of electrolytic activity in this particular system.

Sam D [last name deleted for privacy by Editor]
- Alpine, Texas
(2004)

A.As others have mentioned, there are three different ways for holes to develop in a copper line, and I have seen all three.

A typical trade mark of electrolysis is pit on the inside of the pipe where the electrical current has actually eaten away at the piping, this doesn't sound like what is going on.

Another way is corrosion from the outside, normally when the piping in in a damp location with high acid soils, or even in an unsealed sleeve (copper run inside another pipe, usually PVC, and normally from the meter to the house). This is evidenced by pitting on the outside of the pipe.

The last one I have come across, and am still researching, is what it sounds like this gentleman has. It typically will have build-up on the inside of the piping and will often times leave large "blobs" of build up. I don't know what this is for sure, but I do know it isn't electrolysis, and it has nothing to do with water that is too clean (mentioned on another website as a possible answer). I think it has to do with the water quality to a certain degree, but I think it may be the molecular structure not the chemicals used. I think the buildup is a protectant for a "micro-atmosphere" high in maybe hydrogen. But I could be wrong, I am still researching this. I will post any further findings.

Jereme Grisenti
plumbing - Blountville, Tennessee

(2005)

Q.If we were to rivet or otherwise attach a copper sleeve to galvanized chimney pipe, would this cause the galvanized pipe to fail? We have fireplace chimneys on the beach. we have several copper clad chimneys that are doing well, but the maker went out of business. Now we have only galvanized pipe to work with and the outside of it corroding causes an eye sore.

Bryan Malt
- San Diego, California
(2006)

Q.This is a piggy back question.

Three 1/2 inch copper pipes running from my basement to the Laundry room one floor above show the same kind of erosion as the picture accompanying the original question. In each case the green copper salts and pin holes developed where the pipes pass through the floor. You can see the leaking water from below but not from the laundry room level.

After one of two plumbers to replace one of the leaky pipes stated that at one point he felt a very mild electrically shock, I had an electrician check the system. The electrician said he could not find a problem. The electrician checked the system before and after the plumber felt the shock. We could not duplicate the shock with the plumber or the electrician.

The plumber reinstalled the three pipes and wrapped the new pipes in electrical tape at the point where the pipes go through the floor.

Since we have not yet found a source of electrical charge would it be prudent to ground the copper line to an unused galvanized pipe so any current would flow to the unused galvanized pipe? Any help would be appreciated.

Greg Butts
- Stafford, Virginia
(2007)

Q.When copper pipes are plastered over into walls do they need to be protected from corrosion either by cement or plaster?

Mrs M Bridger
Homeowner - Steyning, West Sussex, England
(2007)

Q.I have a brick wall in my bathroom and want to cut a groove in the brick run the copper pipe inside and cement it back up. Will this have a long term effect on the pipe
thanks daz

Dario Ruberto
designer - Toronto, Canada
(2007)

Q.I have some questions regarding electrolysis, or galvanic corrosion between the copper and galvanized water pipes in my house. The house in on a municipal system and it is my understanding that acidic or soft water is not a problem in my area.

I have extremely low pressure in the upstairs bathrooms, and moderately low on the main floor kitchen. In my basement I have galvanized pipes coming in from the street, they supply the hot water heater, and they run the hot water for a few feet beyond the tank. At one point they are connected directly to copper pipes which take the hot and cold supply upstairs to the bathrooms.

I intend to replace the galvanized pipe, but I am trying to decide whether or not to replace the copper pipes going upstairs, and as well the hot water heater.

To make this decision I need to understand a little more about what is going on with the electrolysis. Before discussing the ramifications with the hot water heater, I have the following questions:

1. Where the galvanized and copper connect in the basement, does the electrolysis happen only locally? It seems that the electrons would travel only within the magnetic field created by the metals and therefore only affect the pipes within about a foot or so of the connection. Or, since the water exists through all the pipes, does the electrolysis affect the copper all the way to the upstairs bathrooms?
2. Once the galvanized pipe is removed, will the electrolysis cease? (I understand that new copper and old copper will also create electrolysis but I assume this condition is not as severe.)
3. I understand why galvanized pipe corrodes when coupled with copper but I don't understand why it is that the galvanized pipe becomes filled with gunk on the inside and restricts flow, I would think the corroding would make it get slightly wider on the inside, not more narrow.
4. If I remove the galvanized pipe, can I clean out the remaining copper pipe to make sure there is no corrosive material setting in them? How is this performed?

As far as the hot water heater is concerned, galvanized pipe feeds it and takes the water out of it, however, there is copper flexible tubing that actually connects directly to it. I assume this means the heater has corrosive material in it and will likely not last as long. If I leave the existing heater in place and wait for it to fail, will it contaminate any new piping that I put in?

Also, if I run the new copper water service through the front yard within a few feet of the gas line will this cause electrolysis? If yes, will it affect the pipes inside the house or just in the front yard? Which pipe will get holes and which will narrow? Can I insulate the copper to prevent this?

Justin Zavislak
buyer, hobbyist - Seattle, Washington
July 13, 2008

Q.I have type k copper coming from the main to the shutoff in the house. after reporting a leak it was dug up to be repaired and all was found was a pipe with walls that have thinned considerably and covered in grooves resembling termite damage on wood. it was also riddled with pinholes.

the ground for my electrical is connected to this pipe. could that be a possible cause. please help. there other houses in the area that have had there lines replaced twice in the last 20 years.

thanks, cy

cyrus lambert
hobbyist - conne river, Newfoundland, Canada
July 20, 2008

A.Where I work they were having problems with the copper pipes. The anode rods in the water storage tanks had been all wore down. Plumbers found the electrical system grounding rod had been disconnected & everything was grounding through the plumbing, causing the problems. You might want to check but I think it is a code violation now to ground through your plumbing only.

Alex Hatfield
- Cedar Rapids, Iowa

August 30, 2008

Q.I have a problem identical to to the lead in this thread. Green spots on rigid type L 1/2 in copper pipe with water seepage. This 14+ ft run of pipe is leading from my gas fired hot water heater (after a few short copper fittings) across the drywall finished basement ceiling to a T that feeds hot water to most of the house. I noticed a small spot of mold on the ceiling, cut it open and found this pipe with green spots like the picture above and two of the spots (at different ends of this one section of pipe) have water seepage. There are several other copper pipes , cold water and feeds for hot water heating that have no green spots,(only this one length of hot water has the spots) and also a flexible gas line in the same bay. My fix is to replace this entire length. A difficult job for me, tight spaces overhead, and hope there are no other bad pipe in the house. Please confirm the cause of this. Is it likely to be elsewhere or reoccur?

David Goldman
- W Milford, New Jersey
September 3, 2008

A.In response to the gentleman who experienced a leak on a 1/2 copper pipe and then he split it exposing this thick green blob running on the inside for some unknown length. well from dealing with similar repairs and from years of experience in the field this green corrosion that you are talking about stands far from electrolysis. this green gunk/blob is what we use to solder/sweat our copper pipes with better known as FLUX this product is applied to the outside of the copper pipe once it has been cleaned and reamed. putting too much flux on the pipe and fitting will cause the excess to flow into the pipe and will settle on the inside of the pipe until the system gets energized and water flows flushing out the excess flux. if it was not flushed out and was left as is; guess what? call your plumber.....thanks.

Armando Olvera
- Costa Mesa, California

September 14, 2008

Q.Within the last 9 weeks we have called the plumber 3 times regarding a 4 ft. section of hot water copper piping. Each time a pinhole sealing leak about 4-6 feet away from a recently replaced(5 months ago that our plumber installed) electric hot water heater. After replacing 2 inch copper pipe sections at a time we finely asked him to change a length of pipe but, only last night we developed another leak, a foot over from the new pipe, closer to the water heater. Our house is 15 years old and we use city water. The leaky pipe had green discoloration at the leak points. The plumber says this problem could be expected in this area in homes using well water after about 20 years due to the highly acidic soil but we use city water and our pipes are in the sealing. He's suggesting we may need to replace all of our pipes but it seems strange that the leaks are all near the water heater. Could the water heater be faulty or it's installation be the problem?

Chris McQuillen
homeowner - Crescent City, California
September 14, 2008

A.Hi, Chris. I'd be pretty confident that is has to do with something electrical rather than well water. I think I'd call an electrician rather than calling the plumber again.

Regards,

Ted Mooney, finishing.com
Teds signature
Ted Mooney, P.E. RET
finishing.com
Pine Beach, New Jersey

(2005)September 30, 2008

Q.can a copper water line be spliced to an existing galvanized water pipe line?

Keith Medved
- Dyer, Indiana

A.Hi, Keith. When you transition from one kind of metal pipe to another, the correct thing to do is to use dielectric unions =>

These are unions that include a plastic insulator so there is no metal-to-metal contact. I'm not saying that this is always done, but it is the right way to insure that there can be no galvanic corrosion.

Regards,

Ted Mooney, finishing.com
Teds signature
Ted Mooney, P.E. RET
finishing.com
Pine Beach, New Jersey

October 24, 2008

Q.How can one determine the cause of frequent deterioration of a 3/4" copper water supply line? The section going bad is located underground at the block wall of the foundation. The home owner had to replace this line two times within the past year. The deterioration seems to occur on the outside of the pipe. There were no problems prior to the first replacement of this pipe section 9 months ago. The home has city water and uses a sump pump due to a high level of ground water. I don't know the pH level of the water. The basement is dry, but uses on a "floating slab" to channel away the ground water. I conducted load tests of the electric panel to verify the electric wiring. All tests proved satisfactory with only about .2 amps or less flowing to the ground wire. This is when a 35 amp load is applied to each 120 volt leg. This proves that practically all current is flowing back through the neutral conductor. The electric service is lacking the required two, 8 foot ground rods. There is only one ground rod, and it appears to have been installed as a ground for the telephone system. At this point I'm thinking the corrosion and deterioration was not caused by excessive current flowing top ground via this water supply line.

Dave Baylor
- Pittsburgh, Pennsylvania
May 22, 2009

Q.Hi, Our house is 6 years old and from the time we moved in we have had this "green" problem. It has ruined my hair and has left stains in the sinks and toilets. We have had 2 different water softeners and 2 water heaters. We discussed this with the last water softener person and I guess they didn't have a clue about this problem. No one has until I
talked to some nerd at the company that tests the water for the city. He said that it was probably because of the fittings that the water softener company put on the copper pipes and if we didn't rectify the problem, we would eventually have pin size holes in the pipes and leaks! What do we do, who do we call and how do we go about fixing this problem! I want long hair again! Thanks!

Kathy L. Maxwell
- Grover Beach, California
December 8, 2009

A.While replacing the copper piping in a 150 year old home, I was puzzled by the green buildup inside of the pipe. Tracing the pipe I discovered that a ground clamp and wire from the circuit breaker box was connected to the cold water line 15' from the water meter where a jumper wire was also connected to the pipe from the street. In the circuit breaker box the Neutral buss was bonded to the Ground buss. That was okay. I also checked the sub panel to make sure the Ground buss and Neutral buss were not connected.

The wire mains from the electrical meter are aluminum. Current will find the least path of resistance, therefore current leakage to the piping is occurring. The remedy for this is to drive a conductive rod into the ground as deep as local code requires and connect a ground wire. Additionally I moved the ground clamp to the incoming side of the water meter, and removed the grounding jumper. As the water meter has dielectric connections the leakage can not return into the water piping since it is no longer grounded.

Bert Cooper
Equipment Designer - Williamsport, Pennsylvania

June 11, 2010

Q.Type K soft copper pinholes. We are having numerous issues with 3/4" and 1" and even a couple 2" services running from the mainline in the street to the property. 10 years ago or so we started having pinhole leaks appear on the copper always next to a flaired fitting so naturally everyone blamed it on a bad flair, then the specs changed and we were allowed to use compression fittings. This is now happening with the compression fittings as well, now everyone is blaming it on not de-burring the copper properly.

We just had to dig up a leak and found the pinhole leak in the middle of the 1" copper run (no fittings even close) and the copper was in a 4" sleeve under a major street which would eliminate the corrosive soil theory which the supplier will want to use, also the leak was on the top of the copper so a rubbing situation is not the answer. I have a question, is it possible for the copper at the time of production to have impurities introduced causing an electrolysis situation? Do you know of any other town having this problem. The suppliers here have no idea and have never even heard of this problem before which I find hard to believe. Thank you for your time and opinion

Bill Williams
water company - Tucson, Arizona
September 9, 2010

Q.I have recently installed and new water softener with an aerater in my home. My home is 26 years old and several weeks after the installation I noticed a blueish/green tint. I have had the water tested and the copper level is high, can the new system cause this?

Rachele Cancia
home owner -Sunrise, Florida
November 26, 2010

Q.I had an odd situation and was wondering if there is a known reason.
Last evening we noticed water dripping from the ceiling. Upon cutting open the ceiling, I noticed that the 3/4 hot water heating pipe (not sure if supply or return) was pressing firmly against the 1/2 hot water supply pipe, and that a leak had developed in the (smaller) hot water pipe where they touched. Fortunately, the heating pipe was connected to flexible copper to go up through the floor, and I was able to push the pipes apart and repair the supply line easily, but I am concerned what might have caused this leak.

Mike Paulson
former kitchen contractor, retired -falls church, Virginia

December 17, 2010

Below is an excerpt from Wikipedia's "Tap Water" page at en.wikipedia.org/wiki/Tap_water

"Pin-hole leaks can occur anytime copper piping is improperly grounded and/or bonded; nonmetal piping, such as Pex or PVC, does not suffer from this problem. The phenomenon is known technically as stray current corrosion or electrolytic pitting. Pin-holing due to poor grounding or poor bonding occurs typically in homes where the original plumbing has been modified; homeowners may find a new plastic water filtration device or plastic repair union has interrupted the water pipe's electrical continuity to ground when they start seeing pinhole water leaks after a recent install. Damage occurs rapidly, usually being seen about six months after the ground interruption."

Q.So if I understand this correctly, adding a union may cause this problem? How does one connect copper pipe to galvanized steel then, or how to bond from copper pipe (cold water line, for example) to iron pipe (gas line, for example)? What materials is the bond conductor made of?

Andy Roberts
-Maynard, Massachusetts

May 13, 2011

A.I have seen electrolysis occur with galv. steel straps, hangers and supports, with copper. It usually occurs at the point.
Pin Hole leaks are mostly caused by incorrect installation of plumbing pipes.
For example, If a plumber uses a pipe cutter, to cut a pipe, it leaves a ridge on the inside of the pipe. This causes a ripple in the flow of water going through the pipe, and will eventually start eating away at the pipe, from the inside out. This was a common occurrence back when track homes were booming, and the track rats were doing high volume production, and not installing correctly.
You can verify this, by separating the pipes at the soldered joint, and stick you finger in the pipe and feel the edge. If you feel a sharp edge, then the fitter never filed the inside edge to remove this. Which this is why it will happen in multiple places in your home. Also the reason it happens more to cold water lines, is because you use your cold water more that your hot.

Keith Van Aalst

-Anaheim California


February 3, 2012 -- this entry appended to this thread by editor in lieu of spawning a duplicative thread

Q.I need to run natural gas to an outside heater. I have a 3/4" gal water line which is no longer used, am hoping to run type 'L' flex 1/2" copper line thru this line to supply gas to out side heater, is that possible or is there something I could wrap the copper with to make it work?

Bob Hendrickson
-Pontiac, Illinois, USA
February 25, 2012

Q.I have a bunch of copper fittings. 1/2", 3/4" & 1"; I had the fittings for a year or more. Some of the fittings are starting to get corrosion on them, a greenish thick coating. What is causing this and how do I control/stop it. All the fittings are new and never used.

Ken Kramlich
-Sacramento, California, USA
February 27, 2012

A.Hi, Ken.

Copper corrodes, but usually not that quickly. The simplest fix is probably to put them in a plastic bag with desiccant. Sodium benzotriazole is a copper preservative. You can use brass lacquer if you are trying to protect them for artistic rather than functional use. Good luck.

Regards,

Ted Mooney, finishing.com
Teds signature
Ted Mooney, P.E. RET
finishing.com
Pine Beach, New Jersey

December 18, 2012

A. After reading all of the postings about plumbing -
There are a lot of factors to touch on.

Any type of pipe can be connected to a different type of pipe with the right connectors that can be found at big box or good hardware store.

The green spots inside or outside of a copper pipe is cause by Flux.
Flux is an acid that is used by plumbers when the copper piped is fitted together and soldered.
When a plumber puts too much flux on the copper fittings or pipe - It stays inside the pipe and causes the pipe and or fittings to corrode because the water does not get hot enough to melt flux in order to get it flushed out of the pipe or fittings.
Even if you air pressure out the lines, all of the flux will not move out of the copper pipe because flux is a paste, and what little amount of flux that does move will stick to any joining type of Copper or Plastic or PVC or Galvanized pipe or fittings.
Green spots on the outside of a copper pipe or fittings usually means the plumber did not wipe off any left over flux on the out side of the copper pipe or fittings, or the copper pipe has started to corrode from the inside out from using too much flux inside the pipe and the flux has made its way to the outside of the copper pipe or fittings and needs to be replaced.

As far as electric or electric ground going through copper - Electricity will slowly soften up the excess flux that was used on the copper pipe or fittings.
As the flux softens, and because Flux is an acid, it will slowly break down the copper pipe or fittings and needs to be replaced.

NOTE:
Most electric or electric ground going through a copper pipe is not a high enough voltage to melt flux -- it will only soften the flux.

NOTE:
If your phone line is grounded to the copper line then this alone is enough to soften the flux.
If you put some flux on both the neg. and pos. post of a small charged 9 volt battery you will find that the flux will soften.
If you leave the flux on the battery the flux will corrode the battery because flux is an acid.

NOTE:
If your phone or cable is grounded to your copper pipe this is enough electric for a person to get a small shock when touching the copper pipe.
After a person touches the pipe and gets a small shock, it takes quite a while for the electric to build back up because the voltage is quite low.
It is because the voltage is so low that when a person touches a copper pipe and gets a small shock you have depleted the electric in the copper pipe and a shock will not happen again until the electric builds back up in the copper pipe.

NOTE:
Anytime you have to run a copper pipe behind a wall that will be closed in, only use HARD copper pipe (NOT ROLLED TUBING OR SOFT TUBING). Place the copper pipe inside of a piece of PVC pipe and do not have any fittings or couplings that have been soldered inside the PVC pipe.
If you need to soldier on fittings - Solder the fittings on after you have cleared the wall that will be closed in. It will also be helpful to use liquid foam between the copper pipe and the PVC pipe to stop any pipes from clanking when the water is turned on or off. You can pre make up the pipe with the foam in order to let the liquid foam set up.

I hope this information is helpful.

Jim Drake
- Fredericksburg, Virginia, USA

April 20, 2013

A.To those dismissing the "green blobs" as residual flux are not understanding what I think are the inquisitors' issues. We built our home in 2004 and within a couple of years we started experiencing problems in our master shower. Initially, I was able to disassemble the hot water supply in the manifolds and clear out the green "blobbish" crystals. Our master shower is large and has multiple shower heads and two shower manifolds. Since then the problem appear to only exist in the master bath "hot" water lines. I have never had any issue with the cold water lines.

To give a little more detail. The green blobs I am experiencing a hard crystals and not any type of pasty or flux consistency. I have found galvanized steel nipples between the copper supply lines and the brass shower fittings. Two years ago the galvanized nipple on the shower with the most serious blockage, had nearly corroded away completely. Fortunately I had decided inspect the inside of the shower wall after suspecting some sort of "electronic" cause. This morning I found the same union on the second shower head that is now almost completely blocked.

I should have recognized something was wrong in the construction of our plumbing lines during the build simply because of the sloppy solder joints. I have a rudimentary knowledge of plumbing as my father was a plumber. Unfortunately, I was traveling extensively and didn't have time to address the bootleg plumbers my builder contracted.
I guess I was depending on the inspectors to alert us of any issues, but I have learned that lesson.

In summary, I would conclude that the green crystals are formed from kind electric current activity in addition to the hardness of your water. Our municipal water is very hard and my water softener is worthless so we are going to rip out the bathroom walls to see what other surprises we have in store and get a new water softening system.

Vaughn Broadnax
- Carmel, Indiana, USA

copper pipe secured with metal straps
May 21, 2013

Q.During a bathroom remodel, the plumber used some metal strapping (likely galvanized steel)to further secure the copper piping from the shower valve to the shower outlet. (see photo) Days later, my contractor had secured a loose toilet supply valve with a plastic part and explained that a metal material could negatively interact with the copper and eventually cause a leak. (I think he himself had just come upon this info when he went to home depot to pick-up the part.)
I then remembered seeing how the plumber used the metal strapping to basically tie back the copper piping. The wall has since been scratch coated and is about to be floated. I've alerted my contractor about this and am awaiting a reply. I really do not want the float to happen until I know for sure that there is definitely no problem with the set-up, or, until it is corrected. Any input on this would greatly be appreciated.

Jack Goldstein
- Mission Viejo, California, USA

May 22, 2013

A.Hi Jack. You need 3 things for galvanic corrosion:
- dissimilar metals so there is an inherent voltage between them,
- metallic contact path between the two metals so that electrons can flow from one metal to the other,
- a moist and conductive ionic path so that positively charged ions can follow the electrons, transporting atoms of metal from one point to another.

You certainly have the first two, but whether the third condition is met well enough for serious concern is always the question, and sometimes hard to define. When such a condition is sealed behind a wall, it sounds to me like poor practice -- then again, I'm not a plumber. You might see if you can find anything in the plumbing code about it. The problem would have been easy to avoid with any kind of plastic between the pipe and strap; you can hopefully get a scrap of Visqueen in between them without much damage to the wall. Good luck.

Regards,

Ted Mooney, finishing.com
Teds signature
Ted Mooney, P.E. RET
finishing.com
Pine Beach, New Jersey

June 3, 2013

Q.Having pin hole issues on the cold water line repeatedly over approx. 8 years -- same area.
The house used to have copper pipe coming in from the street and we did not have a ground strap on it. I can see how the pin holes would happen then. Then the copper pipe was replaced with PVC out to the street so there seemed to be no need for the ground on the street side of the meter, but I left the ground connected on the house side (still copper here). Was this wrong? Still another pin hole problem this year.
Tired of water leaks, Tom

Tom Canarecci
- Mishawaka, Indiana, USA
July 11, 2013

Q.We have an apartment building that keeps getting leaks in the first apartment. I have read everything and understand the problem, but we don't have money to replace all the pipes, so every few months there is a leak. The last time we had to replace all the carpet because it was leaking over a full weekend.

I have been told by one plumber that he heard of a product that can be put in the pipes that would coat the insides and help prevent the pinholes from developing.
Is there any such product?

Also someone told me of a product that can be painted on the pipes like a silicone or latex component that might be able to help.

If you know of any products like this that I can try, please let me know.

Thank you.

Lisa Keylon
- Fountain Valley, California, USA
February 11, 2016

Q. I just noticed there is corrosion at the elbo 90 connector of hot water copper pipe going out of water heater. Both are copper pipes - so wondering what's causing the corrosion. Otherwise I'm planning to
Simply planning to use fix-it stick/Keeny pipe wrap tape as temporary fix until I get time to call plumber to cut the pipe and rejoin.
Please advise:
1) is it ok to fix temporarily
2) if I need to dig in further to find the cause before I fix it.
3) are there any other things I need to check / replace while I'm fixing it.
Btw- this is house is 10 yrs old.

Venu Reddy
- Waukee, Iowa

April 8, 2016

A. You can also use a brass nipple between copper and galvanize .

Rodolfo ruiz
- Pasadena California usa
April 2016

thumbs up signThanks, Rudolfo. Yes, you can use a brass nipple between them ... but I don't think it will do much towards stopping galvanic corrosion.

Regards,

pic of Ted Mooney
Ted Mooney, P.E. RET
finishing.com
Pine Beach, New Jersey
Striving to live "Aloha"

This public forum has 60,000 threads. If your question seems off topic to this thread, you might prefer to search the site:


Disclaimer: It's not possible to diagnose a finishing problem or the hazards of an operation via these pages. All information presented is for general reference and does not represent a professional opinion nor the policy of an author's employer. The internet is largely anonymous & unvetted; some names may be fictitious and some recommendations may be deliberately harmful.